Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Prospective Comparison of Ultra-Low-Dose Versus Standard-Dose Computed Tomography for Esophageal Foreign Body Detection

Zeqiang Ji; Zhijun Yu; Chunying Liu; Jiankui Mu; Hongtao Qin; Ning Wang; Xinshan Guo; Zhanhui Liu; Xing Guan (2026). Journal of Visualized Experiments

DOI 10.3791/69349

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

The objective of this study was to verify the non-inferiority of ultra-low-dose computed tomography (ULD-CT) versus standard-dose CT (SD-CT) for esophageal foreign body (EFB) detection and to quantify dose-quality trade-offs. This prospective, randomized, blinded-reader study enrolled 180 patients (120 adults, 60 children) presenting with suspected EFB ingestion. Patients were randomized to ULD-CT (100 kV/50 mA, adaptive statistical iterative reconstruction-V 80% + deep learning image reconstruction) or SD-CT (120 kV/200 mA, filtered back projection + adaptive statistical iterative reconstruction-V 30%) groups. All patients underwent endoscopic or surgical reference-standard evaluation within 12 h of CT imaging, with 30-day follow-up for negative findings. The primary endpoint was the area under the curve (AUC); secondary endpoints included image quality metrics, radiation dose, and incidental findings. Both protocols achieved excellent diagnostic performance, with sensitivity/specificity of 97.8%/100% for ULD-CT and 98.9%/100% for SD-CT. The AUC was 0.985 for ULD-CT versus 0.991 for SD-CT (difference < non-inferiority margin). The effective dose was reduced by 63% with ULD-CT (P < 0.001). The signal-to-noise ratio decreased by 37% (P < 0.001), yet diagnostic acceptability (score ≥3) was maintained at 94.4% versus 97.8% (P = 0.070). Incidental findings were identified in 54 patients (30.0%), including 19 potentially actionable findings (10.6%) and 6 high-significance findings requiring urgent evaluation. Ultra-low-dose CT demonstrates non-inferior diagnostic accuracy compared with SD-CT for EFB detection while reducing radiation exposure by over 60%. These findings show potential for ULD-CT as a first-line modality for suspected EFBs pending multicenter validation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=241; abstract_english_function_words=60; abstract_english_share=0.2490; abstract_reads=english; language_check=metadata_listed