Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Emphysema Quantification in Inflation-Fixed Lungs Using Low-Dose Computed Tomography and 3He Magnetic Resonance Imaging

David S. Gierada; Jason C. Woods; Richard E. Jacob; Andrew J. Bierhals; Cliff K. C. Choong; Seth T. Bartel; Yulin V. Chang; Nitin A. Das; Cheng Hong; Barbara A. Lutey; Jon H. Ritter; Thomas K. Pilgram; Joel David Cooper; G. Alexander Patterson; Richard James Battafarano; Bryan F. Meyers; Dmitriy A. Yablonskiy; Mark S. Conradi (2010). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0b013e3181e480f9

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with computed tomography (CT) and He magnetic resonance (MR) diffusion imaging. METHODS: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. Computed tomographic measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. RESULTS: The mean (SD) CT emphysema indices were 56% (17%) before and 58% (19%) after fixation (P = 0.77; R = 0.76). Index differences correlated with differences in lung volume (R = 0.47). The mean (SD) 3He ADCs were 0.40 (0.15) cm/s before and 0.39 (0.14) cm/s after fixation (P = 0.03, R = 0.98). The CT emphysema index and the 3He ADC were correlated before (R = 0.89) and after fixation (R = 0.79). CONCLUSIONS: Concordance of CT and 3He MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=162; abstract_english_function_words=48; abstract_english_share=0.2963; abstract_reads=english; language_check=metadata_listed