Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diagnostic Accuracy of Ultra-Low Dose CT Compared to Standard Dose CT for Identification of Fresh Rib Fractures by Deep Learning Algorithm

Pei-Kai Huang; Hongyi Li; Fenghuan Lin; Ming Lei; Meng Zhang; Jingfeng Liu; JunChen; Junfei Hou; Mengqiang Xiao (2024). Journal of Imaging Informatics in Medicine

DOI 10.1007/s10278-024-01027-8

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The present study aimed to evaluate the diagnostic accuracy of ultra-low dose computed tomography (ULD-CT) compared to standard dose computed tomography (SD-CT) in discerning recent rib fractures using a deep learning algorithm detection of rib fractures (DLADRF). A total of 158 patients undergoing forensic diagnosis for rib fractures were included in this study: 50 underwent SD-CT, and 108 were assessed using ULD-CT. Junior and senior radiologists independently evaluated the images to identify and characterize the rib fractures. The sensitivity of rib fracture diagnosis by radiologists and radiologist + DLADRF was better using SD-CT than ULD-CT. However, the diagnosis sensitivity of DLADRF using ULD-CT alone was slightly more than SD-CT. Nonetheless, no substantial differences were observed in specificity, positive predictive value, and negative predictive value between SD-CT and ULD-CT by the same radiologist, radiologist + DLADRF, and DLADRF (P > 0.05). The area under the curve (AUC) of receiver operating characteristic indicated that senior radiologist + DLADRF was significantly better than senior and junior radiologists, junior radiologists + DLADRF, and DLADRF alone using SD-CT or ULD-CT (all P < 0.05). Also, junior radiologists + DLADRF was better with ULD-CT than senior and junior radiologists (P < 0.05). The AUC of the rib fracture diagnosed by senior radiologists did not differ from DLADRF using ULD-CT. Also, no significant differences were observed between junior + AI and senior and between junior and DLADRF using SD-CT. DLADRF enhanced the diagnostic performance of radiologists in detecting recent rib fractures. The diagnostic outcomes between SD-CT and ULD-CT across radiologists' experience and DLADRF did not differ significantly.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=5; title_english_share=0.2273; title_reads=english; abstract_words=263; abstract_english_function_words=81; abstract_english_share=0.3080; abstract_reads=english; language_check=metadata_listed