A phantom study investigating the relationship between ground‐glass opacity visibility and physical detectability index in low‐dose chest computed tomography

Katsuhiro Ichikawa; Takeshi Kobayashi; Motoyasu Sagawa; 亜矢子 片桐; Yukiko Uno; Ryo Nishioka; Jun Matsuyama (2015). Journal of Applied Clinical Medical Physics

DOI 10.1120/jacmp.v16i4.5001

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

In this study, the relationship between ground-glass opacity (GGO) visibility and physical detectability index in low-dose computed tomography (LDCT) for lung cancer screening was investigated. An anthropomorphic chest phantom that included synthetic GGOs with CT numbers of -630 Hounsfield units (HU; high attenuation GGO: HGGO) and -800 HU (low attenuation GGO: LGGO), and three phantoms for physical measurements were employed. The phantoms were scanned using 12 CT systems located in 11 screening centers in Japan. The slice thicknesses and CT dose indices (CTDI(vol)) varied over 1.0-5.0 mm and 0.85-3.30 mGy, respectively, and several reconstruction kernels were used. Physical detectability index values were calculated from measurements of resolution, noise, and slice thickness properties for all image sets. Five radiologists and one thoracic surgeon, blind to one another's observations, evaluated GGO visibility using a five-point scoring system. The physical detectability index correlated reasonably well with the GGO visibility (R² = 0.709, p < 0.01 for 6 mm HGGO and R² = 0.646, p < 0.01 for 10 mm LGGO), and was nearly proportional to the CTDI(vol). Consequently, the CTDI(vol) also correlated reasonably well with the GGO visibility (R² = 0.701, p < 0.01 for 6 mm HGGO and R² = 0.680, p < 0.01 for 10 mm LGGO). As a result, the CTDI(vol) was nearly dominant in the GGO visibility for image sets with different reconstruction kernels and slice thicknesses, used in this study.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=5; title_english_share=0.2381; title_reads=english; abstract_words=214; abstract_english_function_words=65; abstract_english_share=0.3037; abstract_reads=english; language_check=metadata_listed