Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Feasibility analysis of low-dose CT with asynchronous quantitative computed tomography to assess vBMD

Tingting Hu; Xingyuan Yang; Lei Gao; Ying Liu; Wei Zhang; Yan Wang; Xiaona Zhu; Xiangdong Liu; Hongran Liu; Xiaohui Ma (2023). BMC Medical Imaging

DOI 10.1186/s12880-023-01115-1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Background To explore the feasibility of low-dose computed tomography (LDCT) with asynchronous quantitative computed tomography (asynchronous QCT) for assessing the volumetric bone mineral density (vBMD). Methods 416 women patients, categorized into 4 groups, were included and underwent chest CT examinations combined with asynchronous QCT, and CT scanning dose protocols (LDCT or CDCT) were self-determined by the participants. Radiation dose estimations were retrieved from patient protocols, including volume CT dose index (CTDIvol) and dose-length-product (DLP), and then calculated effective dose (ED). Delimiting ED by 1.0 mSv, chest CT examinations were categorized into 2 groups, LDCT group and CDCT group. vBMD of T12-L2 was obtained by transferring the LDCT and CDCT images to the QCT workstation, without extra radiation. Results There was no difference of vBMD among 4 age groups in LDCT group (P = 0.965), and no difference in CDCT group (P = 0.988). In LDCT group and CDCT group, vBMD was not correlated to mAs, CTDIvol and DLP (P > 0.05), respectively. Between LDCT group and CDCT group, there was no difference of vBMD (P ≥ 0.480), while differences of mAs, CTDIvol and DLP. Conclusion There was no difference of vBMD between LDCT group and CDCT group and vBMD was not correlated to mAs. While screening for diseases such as lung cancer and mediastinal lesions, LDCT combined with asynchronous QCT can be also used to assess vBMD simultaneously with no extra imaging equipment, patient visit time, radiation dose and no additional economic cost.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=237; abstract_english_function_words=74; abstract_english_share=0.3122; abstract_reads=english; language_check=metadata_listed