Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Feasibility of rib fracture detection in low-dose computed tomography images with a large, multicenter datasets-based model

Liang Jin; E. Youjun; Zheng Ye; Pan Gao; Guoliang Wei; Jia qi Zhang; Ming Li (2024). Heliyon

DOI 10.1016/j.heliyon.2024.e31010

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Purpose: To evaluate the feasibility of rib fracture detection in low-dose computed tomography (CT) images with a RetinaNet-based approach and to evaluate the potential of lowdose CT for rib fracture detection compared with regular-dose CT images. Materials and methods: The RetinaNet-based deep learning model was trained using 7300 scans with 50,410 rib fractures that were used as internal training datasets from four multicenter. The external test datasets consisted of both regular-dose and low-dose chest-abdomen CT images of rib fractures; the MICCAI 2020 RibFrac Challenge Dataset was used as the public dataset. Radiologists' interpretations were used as reference standards. The performance of the model in rib fracture detection was compared with the radiologists' interpretation. Results: In total, 728 traumatic rib fractures of 100 patients [60 men (60 %); mean age, 53.45 ± 11.19 (standard deviation (SD)); range, 18-77 years] were assessed in the external datasets. In these patients, the regular-dose group had a mean CT dose index volume (CTDIvol) of 7.18 mGy (SD: 2.22) and a mean dose length product (DLP) of 305.38 mGy cm (SD: 95.31); the low-dose group had a mean CTDIvol of 2.79 mGy (SD: 1.11) and a mean DLP of 131.52 mGy cm (SD: 55.58). The sensitivity of the RetinaNet-based model and that of the radiologists was 0.859 and 0.721 in the low-dose CT images and 0.886 and 0.794 in the regular-dose CT images, respectively. Conclusions: These findings indicate that the RetinaNet-based model can detect rib fractures in low-dose CT images with a robust performance, indicating its feasibility in assisting radiologists with rib fracture diagnosis.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=248; abstract_english_function_words=84; abstract_english_share=0.3387; abstract_reads=english; language_check=metadata_listed