Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Usefulness of 67Ga SPECT and integrated low-dose CT scanning (SPECT/CT) in the diagnosis of cardiac sarcoidosis

Mitsuhiro Momose; Masumi Kadoya; Megumi Koshikawa; Tsuyoshi Matsushita; Akira Yamada (2007). Annals of Nuclear Medicine

DOI 10.1007/s12149-007-0064-5

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: We performed 67Gallium (Ga) single-photon emission computed tomography (SPECT) with integrated low-dose computed tomography (CT) for the interpretation of myocardial outline to investigate the value of co-registered fusion imaging using a hybrid system (SPECT/CT) in patients with cardiac sarcoidosis. METHODS: SPECT/CT of the region in question was performed with VG Hawkeye. The subjects in this study were 37 patients [mean (+/-SD) age 61.0+/-13.0 years; 12 men and 25 women], 13 of whom had a clinical diagnosis of cardiac sarcoidosis and 24 a negative diagnosis. An intravenous injection of Ga (dosage 111 MBq) was performed on patients 48 h or 72 h before obtaining static planar images of the whole-body and the SPECT/CT scan. RESULTS: Abnormal Ga uptake in the myocardium was observed in 10 of the 13 subjects with true sarcoidosis, and in 11 of 24 with negative sarcoidosis without CT fusion. The sensitivity without CT fusion was 77%, the specificity 54%, and the accuracy 62%. Use of SPECT/CT changed the diagnosis only in a patient with true sarcoidosis, and changed the diagnosis in eight patients with negative sarcoidosis. The sensitivity with CT fusion was 69%, the specificity 79%, and the accuracy 76%. The difference in diagnostic accuracy was statistically significant (McNemar's test, P=0.039). CONCLUSIONS: SPECT scanning using Ga and integrated low-dose CT is a very useful diagnostic imaging technique because it improves the diagnostic specificity of Ga SPECT to allow the highly specific diagnosis of cardiac sarcoidosis.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=5; title_english_share=0.2778; title_reads=english; abstract_words=230; abstract_english_function_words=85; abstract_english_share=0.3696; abstract_reads=english; language_check=metadata_listed