Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Whole-Body Computed Tomography Using Low-Dose Biphasic Injection Protocol With Adaptive Statistical Iterative Reconstruction V: Assessment of Dose Reduction and Image Quality in Trauma Patients

Ali H. Elmokadem; Enas A. Ibrahim; Walaa A. Gouda; Ahmed Abdel Khalek Abdel Razek (2019). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0000000000000907

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Aim This study aimed to evaluate potential dose savings on a revised protocol for whole-body computed tomography and image quality after implementing Adaptive Statistical Iterative Reconstruction V (ASiR-V) algorism for trauma patients and compare it with routine protocol. Materials and Methods One hundred trauma patients were classified into 2 groups using 2 different scanning protocols. Group A (n = 50; age, 32.48 ± 8.09 years) underwent routine 3-phase protocol. Group B (n = 50; age, 35.94 ± 13.57 years) underwent biphasic injection protocol including unenhanced scan for the brain and cervical spines, followed by a 1-step acquisition of the thorax, abdomen, and pelvis. The ASiR-V level was kept at 50% for all examinations, and then studies were reconstructed at 0% ASiR-V level. Radiation dose, total acquisition time, and image count were compared between groups (A and B). Two radiologists independently graded image quality and artifacts between both groups and 2 ASiR-V levels (0 and 50%). Results The mean (±SD) dose-length product value for postcontrast scans in group A was 1602.3 ± 271.8 mGy · cm and higher when compared with group B (P < 0.001), which was 951.1 ± 359.6 mGy · cm. Biphasic injection protocol gave a dose reduction of 40.4% and reduced the total acquisition time by 11.4% and image count by 37.6%. There was no statistically significant difference between the image quality scores for both groups; however, group A scored higher grades (4.62 ± 0.56 and 4.56 ± 0.67). Similarly, the image quality scores for both ASiR-V levels in both groups were not significantly different. Conclusions Biphasic computed tomography protocol reduced radiation dose with maintenance of diagnostic accuracy and image quality after implementing ASiR-V algorism.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=26; title_english_function_words=4; title_english_share=0.1538; title_reads=english; abstract_words=251; abstract_english_function_words=79; abstract_english_share=0.3147; abstract_reads=english; language_check=metadata_listed