Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Observer Sensitivity for Detection of Pulmonary Nodules in Ultra-Low Dose Computed Tomography Protocols Using a Third-Generation Dual-Source CT with Ultra-High Pitch—A Phantom Study

Natascha Leitzig; Sonja Janssen; Hany Kayed; Stefan O. Schönberg; Hans Scheffel (2023). Anatomia

DOI 10.3390/anatomia2010002

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

This study evaluates ultra-low-dose computed tomography (ULDCT) protocols concerning the detectability of pulmonary nodules. The influence of tube current settings, kernels, strength levels of third-generation iterative reconstruction algorithms, and pitch was investigated. A chest phantom with artificial spherical nodules of different densities and diameters was examined with a third-generation dual-source CT. Scanning and post-processing protocols, tube current levels, and ultra-high and non-high pitch modes were applied. Images were reconstructed with filtered back-projection (FBP) or advanced model-based iterative reconstruction (ADMIRE) algorithms. Sharp (Bl57) or medium-soft (Br36) convolution kernels were applied. The reading was performed by an experienced and an inexperienced reader. The highest observer sensitivity was found using a non-high pitch protocol at tube currents of 120 mAs and 90 mAs with the sharp kernel and iterative reconstruction level of 5. Non-high pitch protocols showed better detectability of solid nodules. Combinations with the medium-soft kernel achieved slightly higher observer sensitivity than with the sharp kernel. False positives (FP) occurred more often for subsolid nodules, at a tube current level of 120 mAs, and with the sharp kernel. A tube current level of 90 mAs combined with the highest iterative reconstruction level achieved the highest accuracy in lung nodule detection regardless of size, density, and reader experience.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=28; title_english_function_words=6; title_english_share=0.2143; title_reads=english; abstract_words=214; abstract_english_function_words=62; abstract_english_share=0.2897; abstract_reads=english; language_check=metadata_listed