Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Dose spread functions in computed tomography: A Monte Carlo study

John M. Boone (2009). Medical Physics

DOI 10.1118/1.3223634

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Purpose:Current CT dosimetry employing CTDI methodology has come under fire in recent years, partially in response to the increasing width of collimated x‐ray fields in modern CT scanners. This study was conducted to provide a better understanding of the radiation dose distributions in CT.Methods:Monte Carlo simulations were used to evaluate radiation dose distributions along the axis arising from CT imaging in cylindrical phantoms. Mathematical cylinders were simulated with compositions of water, polymethyl methacrylate (PMMA), and polyethylene. Cylinder diameters from were studied. X‐ray spectra typical of several CT manufacturers (80, 100, 120, and ) were used. In addition to no bow tie filter, the head and body bow tie filters from modern General Electric and Siemens CT scanners were evaluated. Each cylinder was divided into three concentric regions of equal volume such that the energy deposited is proportional to dose for each region. Two additional dose assessment regions, central and edge locations in diameter, were included for comparisons to measurements. Dose spread functions (DSFs) were computed for a wide number of imaging parameters.Results:DSFs generally exhibit a biexponential falloff from the position. For a very narrow primary beam input , DSFs demonstrated significant low amplitude long range scatter dose tails. For body imaging conditions ( diameter in water), the DSF at the center showed at full width at tenth maximum (FWTM), while at the edge the FWTM was . Polyethylene phantoms exhibited wider DSFs than PMMA or water, as did higher tube voltages in any material. The FWTM were 80, 180, and for 10, 30, and phantom diameters, respectively, at the center in water at with a typical body bow tie filter. Scatter to primary dose ratios (SPRs) increased with phantom diameter from 4 at the center ( diameter) for a diameter cylinder to for a diameter cylinder. The SPRs increased dramatically at the center of the phantom compared to the edge. For the three equal area regions, the edge to center SPRs for a diameter phantom were , 3.5, and 6.3, respectively.Conclusions:DSFs demonstrate low amplitude long ranging tails which reach considerable distances in cylindrical phantoms. The buildup that results from these long‐ranged tails increases at the center of the field (at) with increasing scan length. The DSF distributions lend a better understanding of the trends in CT dose deposition over a range of relevant imaging parameters. The DSFs as well as other related data are available to interested parties using EPAPS at http://www.aip.org/pubservs/epaps.html.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=10; title_english_function_words=2; title_english_share=0.2000; title_reads=english; abstract_words=402; abstract_english_function_words=145; abstract_english_share=0.3607; abstract_reads=english; language_check=metadata_listed