Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Epicardial fat Tissue Volumetry: Comparison of Semi-Automatic Measurement and the Machine Learning Algorithm

Valeria Chernina; Maxim Pisov; Mikhail Belyaev; I. V. Bekk; K. A. Zamyatina; Т. А. Корб; O. O. Aleshina; E. A. Shukina; Alexander V. Solovev; R. A. Skvortsov; Daria A. Filatova; Dmitry Sitdikov; Anna Chesnokova; Sergey Pavlovich Morozov; V. A. Gombolevsky (2020). Kardiologiia

DOI 10.18087/cardio.2020.9.n1111

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Aim To compare assessments of epicardial adipose tissue (EAT) volumes obtained with a semi-automatic, physician-performed analysis and an automatic analysis using a machine-learning algorithm by data of low-dose (LDCT) and standard computed tomography (CT) of chest organs.Material and methods This analytical, retrospective, transversal study randomly included 100 patients from a database of a united radiological informational service (URIS). The patients underwent LDCT as a part of the project "Low-dose chest computed tomography as a screening method for detection of lung cancer and other diseases of chest organs" (n=50) and chest CT according to a standard protocol (n=50) in outpatient clinics of Moscow. Each image was read by two radiologists on a Syngo. via VB20 workstation. In addition, each image was evaluated with a developed machine-learning algorithm, which provides a completely automatic measurement of EAT.Results Comparison of EAT volumes obtained with chest LDCT and CT showed highly consistent results both for the expert-performed semi-automatic analyses (correlation coefficient >98 %) and between the expert layout and the machine-learning algorithm (correlation coefficient >95 %). Time of performing segmentation and volumetry on one image with the machine-learning algorithm was not longer than 40 sec, which was 30 times faster than the quantitative analysis performed by an expert and potentially facilitated quantification of the EAT volume in the clinical conditions.Conclusion The proposed method of automatic volumetry will expedite the analysis of EAT for predicting the risk of ischemic heart disease.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=ru; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=241; abstract_english_function_words=85; abstract_english_share=0.3527; abstract_reads=english; language_check=both_english