Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose CT for the spatial normalization of PET images: A validation procedure for amyloid-PET semi-quantification

Luca Presotto; Leonardo Iaccarino; Arianna Sala; Emilia Giovanna Vanoli; Cristina Muscio; Anna Nigri; Maria Grazia Bruzzone; Fabrizio Tagliavini; Luigi Gianolli; Daniela Perani; Valentino Bettinardi (2018). NeuroImage Clinical

DOI 10.1016/j.nicl.2018.07.013

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The reference standard for spatial normalization of brain positron emission tomography (PET) images involves structural Magnetic Resonance Imaging (MRI) data. However, the lack of such structural information is fairly common in clinical settings. This might lead to lack of proper image quantification and to evaluation based only on visual ratings, which does not allow research studies or clinical trials based on quantification. PET/CT systems are widely available and CT normalization procedures need to be explored. Here we describe and validate a procedure for the spatial normalization of PET images based on the low-dose Computed Tomography (CT) images contextually acquired for attenuation correction in PET/CT systems. We included N = 34 subjects, spanning from cognitively normal to mild cognitive impairment and dementia, who underwent amyloid-PET/CT (18F-Florbetaben) and structural MRI scans. The proposed pipeline is based on the SPM12 unified segmentation algorithm applied to low-dose CT images. The validation of the normalization pipeline focused on 1) statistical comparisons between regional and global 18F-Florbetaben-PET/CT standardized uptake value ratios (SUVrs) estimated from both CT-based and MRI-based normalized PET images (SUVrCT, SUVrMRI) and 2) estimation of the degrees of overlap between warped gray matter (GM) segmented maps derived from CT- and MRI-based spatial transformations. We found negligible deviations between regional and global SUVrs in the two CT and MRI-based methods. SUVrCT and SUVrMRI global uptake scores showed negligible differences (mean ± sd 0.01 ± 0.03). Notably, the CT- and MRI-based warped GM maps showed excellent overlap (90% within 1 mm). The proposed analysis pipeline, based on low-dose CT images, allows accurate spatial normalization and subsequent PET image quantification. A CT-based analytical pipeline could benefit both research and clinical practice, allowing the recruitment of larger samples and favoring clinical routine analysis.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=5; title_english_share=0.2778; title_reads=english; abstract_words=292; abstract_english_function_words=80; abstract_english_share=0.2740; abstract_reads=english; language_check=metadata_listed