Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Monitoring change in volume of calcifications in juvenile idiopathic inflammatory myopathy: a pilot study using low dose computed tomography

Maria F. Ibarra; Cynthia K. Rigsby; Gabrielle A Morgan; Christina L. Sammet; Chiang‐Ching Huang; Xu D; Ira N. Targoff; Lauren M. Pachman (2016). Pediatric Rheumatology

DOI 10.1186/s12969-016-0123-3

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Dystrophic calcifications may occur in patients with J uvenile Idiopathic Inflammatory Myopathy (JIIM) as well as other connective tissue and metabolic diseases, but a reliable method of measuring the volume of these calcifications has not been established. The purpose of this study is to determine the feasibility of low dose, limited slice, Computed Tomography (CT) to measure objectively in-situ calcification volumes in patients with JIIM over time. Ten JIIM patients (eight JDM, two Overlap) with calcifications were prospectively recruited over a 2-year period to undergo two limited, low dose, four-slice CT scans. Calculation of the volume of calcifications used a CT post processing workstation. Additional patient data included: Disease Activity Scores (DAS), Childhood Myositis Assessment Scale (CMAS), myositis specific antibodies (MSA), and the TNFα-308 promoter region A/G polymorphism. Statistical analysis utilized the Pearson correlation coefficient, the paired t -test and descriptive statistics. Ten JIIM, mean age 14.54 ± 4.54 years, had a duration of untreated disease of 8.68 ± 5.65 months MSA status: U1RNP (1), PM-Scl (1), Ro (1, 4 indeterminate), p155/140 (2), MJ (3), Mi-2 indeterminate (1), negative (3). 4/8 JDM (50%) were TNF-α-308 A+. Overall, the calcification volumes tended to decrease from the first to the second CT study by 0.5 cm 3 (from 2.79 ± 1.98 cm 3 to 2.29 ± 2.25 cm 3 ). The average effective radiation dose was 0.007 ± 0.002, 0.010 ± 0.005, and 0.245 mSv for the upper extremity, lower extremity and chest, respectively (compared to a standard chest x-ray-- 0.02mSV effective dosage). We conclude: 1) the limited low dose CT technique provides objective data about volume of the calcifications in JIIM; 2) measuring the volume of calcifications in an extremity is associated with minimal radiation exposure; 3) This method may be useful to evaluate the efficacy of therapies for JIIM dystrophic calcification.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=4; title_english_share=0.2105; title_reads=english; abstract_words=271; abstract_english_function_words=84; abstract_english_share=0.3100; abstract_reads=english; language_check=metadata_listed