Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study

Sungjin Yoon; Kwai Han Yoo; So Hyun Park; Hawk Kim; Jae Hoon Lee; Jinny Park; Seong Ho Park; Hwa Jung Kim (2022). PLOS ONE

DOI 10.1371/journal.pone.0272356

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

This study aimed to evaluate image quality, the detection rate of enlarged lymph nodes, and radiation dose exposure of ultralow-dose and low-dose abdominopelvic computed tomography (CT) in patients with lymphoma. Patients with lymphoma who underwent abdominopelvic CT using dual-source scanner were retrospectively recruited from a single center. CT images were obtained at 90 kVp dual-source mode reformatted in three data sets using the advanced modelled iterative reconstruction algorithm: 100% (standard-dose CT), 66.7% (low-dose CT), and 33.3% (ultralow-dose CT). Two radiologists analyzed subjective image quality and detection of abdominal enlarged lymph nodes on ultralow-dose, low-dose, and standard-dose CT blindly and independently. The results were compared with reference standards. Three readers (two radiologists and one hematologist) reviewed overall image quality and spleen size. In total, 128 consecutive CT scans (77 complete response, 44 partial response, 6 progressive disease, and 1 initial evaluation) from 86 patients (64 B-cell lymphoma, 14 T/NK-cell lymphoma, and 8 Hodgkin’s lymphoma cases) were assessed. The enlarged lymph node-based detection rates for two readers were 97.0% (96/99) and 94.0% (93/99) on standard-dose CT, 97.0% (96/99) and 94.0% (93/99) on low-dose CT, and 94.0% (93/99) and 89.9% (89/99) on ultralow-dose CT. Overall image quality was 3.8 ± 0.5, 3.9 ± 0.5, and 4.1 ± 0.5 on ultralow-dose CT; 4.7 ± 0.4, 4.6 ± 0.5, and 4.8 ± 0.3 on low-dose CT; and 4.8 ± 0.4, 4.7 ± 0.4, and 4.9 ± 0.2 on standard-dose CT, according to two radiologists and one hematologist, respectively. Intraclass correlation coefficients of spleen size were 0.90 (95% confidence interval [CI], 0.87–0.93), 0.91 (95% CI, 0.88–0.93), and 0.91 (95% CI, 0.88–0.93) on ultralow-dose, low-dose, and standard-dose CT, respectively. Mean effective radiation doses of standard-dose, low-dose, and ultralow-dose CT were 5.7 ±1.8 mSv, 3.8 ± 1.2 mSv, and 1.9 ± 0.6 mSv, respectively. Our findings suggest that ultralow-dose and low-dose CT, even with radiation doses reduced by 66.7% and 33.3%, respectively, maintained adequate image quality. These imaging modalities may be employed for follow-up lymphoma evaluation in consideration of the long surveillance periods.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=294; abstract_english_function_words=76; abstract_english_share=0.2585; abstract_reads=english; language_check=metadata_listed