Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

The negative sigmoid loss for controlling false positive rate in osteolytic lesion segmentation

Martijn P. van Leeuwen; Thijs R. van Oudheusden; Sebastiaan Pascal Oei; Bastiaan E. Steunenberg; Johan F. Kint; Erik R. Ranschaert; Gerlof P. T. Bosma; Heeres M. Heres; Eric O. Postma; Koen V. Haak; Görkem Saygılı; L.L. Sharon Ong (2026). Computers in Biology and Medicine

DOI 10.1016/j.compbiomed.2026.111713

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Multiple Myeloma (MM) is a malignancy that is commonly associated with the development of osteolytic lesions. To support MM diagnosis, low-dose Computed Tomography (CT) is commonly used for lesion localization, but manually evaluating CT scans can be time-consuming and prone to error. Although deep learning methods have delivered promising results in supporting lesion detection, they are likely to produce false positive findings, hindering their usability in clinical practice. To address this, we trained a 2D U-Net on annotated lesions (positive patches) in combination with images of bone tissue without lesions (negative patches). To optimize penalization of segmentations in these negative patches, we propose the “Negative Sigmoid” (NS) loss, a term that can be added to conventional loss functions such as the Combo loss (a combination of the cross-entropy and Dice loss). This NS loss applies a tunable penalty to segmentations in negative patches, and by scaling the contribution of the NS loss to the total loss, the balance between lesion detection and false positive rate can be controlled. Compared to training exclusively on positive patches, we show that training with negative patches slightly reduces the number of false positive lesion segmentations in negative patches when using the Combo loss, but that false positive counts can be further reduced by extending the Combo loss with the NS loss. Although the reduced false-positive rate was accompanied by a lower recall and lesion detection rate, it resulted in a significant improvement in precision. Overall, our work demonstrates advances in the automatic segmentation of osteolytic lesions in low-dose CT data by enabling precise control over the number of true and false positives while maintaining good segmentation performance, both of which are key prerequisites for future clinical application. • Training with the Combo loss ineffectively penalizes false positive segmentations in negative patches. • The Negative Sigmoid (NS) loss applies a near size-independent penalty to high-intensity false positives in negative patches. • Adopting the NS loss reduces false positive rates and increases precision, but reduces recall and lesion detection rates. • Scaling the contribution of the NS loss allows for a controllable trade-off between lesion detection and false-positive rate.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=359; abstract_english_function_words=125; abstract_english_share=0.3482; abstract_reads=english; language_check=metadata_listed