Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Segmentation-Driven Dual-Path Network for Low-Dose CT Image Denoising

Shikai Guo; J M Li; Yi Wu (2026). International Conference on Artificial Intelligence and Industrial Technology Applications (AIITA)

DOI 10.1109/aiita69518.2026.11567272

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

In recent years, deep learning has made significant progress in low-dose computed tomography (LDCT) image denoising. However, existing denoising algorithms often cause blurring of anatomical edges and the loss of task-relevant semantic features when applied to downstream clinical segmentation tasks. To balance high-fidelity denoising visual quality and downstream clinical segmentation accuracy, we propose a Segmentation-Driven Dual-Path Network (SD-DPN). Based on a parameterefficient fine-tuning strategy, this model freezes the parameters of a pre-trained multi-scale residual dense transformer backbone and introduces a Multi-Level Feature Adapter (MLFA) to achieve dynamic alignment of spatial details and semantic information. Meanwhile, a dual-path edge enhancement mechanism is designed, and MedSAM, a pre-trained medical image foundation model, is utilized to extract high-level semantic priors for joint constraints. Experimental results on the TotalSegmentator dataset demonstrate that SD-DPN achieves optimal performance in both denoising and segmentation tasks. For denoising, it achieves a Peak Signal-to-Noise Ratio (PSNR) of 32.1590 and a Structural Similarity Index Measure (SSIM) of 0.8977, improving upon the original LDCT by 1.53 and 0.1068, respectively. In the downstream segmentation task of five core organs, its average Dice Similarity Coefficient (DSC) reaches 0.7932, surpassing the segmentation accuracy of normal-dose CT (NDCT). This study provides an efficient solution for the smooth transition of LDCT image denoising to automated clinical organ segmentation.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=11; title_english_function_words=1; title_english_share=0.0909; title_reads=not_english; abstract_words=224; abstract_english_function_words=61; abstract_english_share=0.2723; abstract_reads=english; language_check=metadata_listed