Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Assessment of Calcium Score Cutoff Point for Clinically Significant Aortic Stenosis on Lung Cancer Screening Program Low-Dose Computed Tomography—A Cross-Sectional Analysis

Kaja Klein-Awerjanow; Witold Rzyman; Robert Dziedzic; Jadwiga Fijałkowska; Piotr Spychalski; Edyta Szurowska; Marcin Fijałkowski (2023). Diagnostics

DOI 10.3390/diagnostics13020246

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) is predominantly applied in lung cancer screening programs. Tobacco smoking is the main risk factor for developing lung cancer but is also common for cardiovascular diseases, including aortic stenosis (AS). Consequently, an increased prevalence of cardiovascular diseases is expected in lung cancer screenees. Therefore, initial aortic valve calcification evaluation should be additionally performed on LDCT. The aim of this study was to estimate a calcium score (CS) cutoff point for clinically significant AS diagnosis based on LDCT, confirmed by echocardiographic examination. The study included 6631 heavy smokers who participated in a lung cancer screening program (MOLTEST BIS). LDCTs were performed on all individuals and were additionally assessed for aortic valve calcification with the use of CS according to the Agatston method. Patients with CS ≥ 900 were referred for echocardiography to confirm the diagnosis of AS and to evaluate its severity. Of 6631 individuals, 54 met the inclusion criteria and underwent echocardiography for confirmation and assessment of AS. Based on that data, receiver operating characteristic (ROC) curves of CS were plotted, and cutoff points for clinically significant AS diagnosis were established: A CS of 1758 for at least moderate AS had 85.71% (CI 65.36-95.02%) sensitivity and 75.76% (CI 58.98-87.17%) specificity; a CS of 2665 for severe AS had 87.5% (CI 73.89-94.54%) sensitivity and 76.92% (CI 49.74-91.82%) specificity. This is the first study to assess possible CS cutoff points for diagnosing clinically significant AS detected by LDCT in lung cancer screening participants. LDCT with CS assessment could enable early detection of patients with clinically significant AS and therefore identify patients who require appropriate treatment.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=24; title_english_function_words=4; title_english_share=0.1667; title_reads=english; abstract_words=253; abstract_english_function_words=97; abstract_english_share=0.3834; abstract_reads=english; language_check=metadata_listed