Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

High agreement of coronary artery calcification scores between full-dose (6.5 ​mSv) and reduced-dose (1.5 ​mSv) chest computed tomography: A retrospective analysis of COPDGene

Jeff M. Moore; Katherine A. Pratte; Carrie Ferguson; Richard Casaburi; Beshoy Iskander; Asghar Abbasi; Prakhyat Alapati; Sreya Chilukuri; Aditya Narashim; Matthew J. Budoff; Harry B. Rossiter (2026). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2026.04.008

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Coronary artery calcification (CAC) is a specific feature of atherosclerotic cardiovascular disease. Continued improvements in computed tomography (CT) technology may complicate CAC progression assessment in longitudinal studies that change scanner protocols. Herein, we assessed agreement in CAC measures derived from consecutive non-ECG-gated, chest CT scans performed on the same visit and differing only in radiation dose. METHODS: Agreement in quantitative CAC scores and CAC score categories were determined from a subset of COPDGene participants (N ​= ​115; age: 66 (9) years; 50% male) who received full- (mean effective radiation dose of 6.5 (1.0) mSv) and reduced- (1.5 (0.7) mSv) dose non-ECG-gated CT chest scans at maximal inspiration during their Phase 2 COPDGene study visit. RESULTS: = ​0.96, SE ​= ​0.01, 95% CI: 0.95-0.98). With the full-dose protocol as reference, the reduced-dose protocol had high sensitivity and specificity for determining CAC presence, 94.5% (95%CI: 87.6%-98.2%) and 100% (95% CI: 85.8%-100%), respectively. A Bland-Altman analysis revealed a non-significant higher CAC score with the full-dose protocol: mean bias between protocols of 26 with 95% limits of agreement of -185 to 237. CONCLUSION: CAC scores from non-ECG-gated, chest CT scans are robust to changes in radiation dose at the group level; however, when CAC burden increases, the variability of the CAC score differences increases. GOV IDENTIFIER: NCT00608764.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=23; title_english_function_words=5; title_english_share=0.2174; title_reads=english; abstract_words=200; abstract_english_function_words=55; abstract_english_share=0.2750; abstract_reads=english; language_check=metadata_listed