Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Requirements for Physico-Technical Quality Assurance in the Framework of Early Detection of Lung Cancer
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
According to the text of the Lung Cancer Screening Ordinance on the permissibility of using low-dose computed tomography to screen smokers (LuKrFrühErkV, §7 Quality Assurance, 1), the "radiation protection officer must establish and operate a comprehensive quality assurance system. This must take account of organizational, medical, and technical aspects, in particular [...] 2. the diagnostic image quality of the computed tomography scan, 3. the physical-technical parameters for the acquisition of the computed tomography scan [...]". The German Radiological Society (DRG) considers itself responsible for making recommendations regarding the implementation of such a quality assurance system, in order to provide users with legal certainty and ensure patient safety. The DRG's Physics and Technology Working Group has thus identified the main issues regarding quality assurance for technology, outlined the related challenges, and proposed potential areas for future investigation and resolution (see sections I-V). Existing quality assurance measures for technology must be checked for their suitability with regard to a low-dose screening program and adapted, if necessary. Complex additional constancy tests and the use of special (anthropomorphic) phantoms are not currently considered necessary. The tasks of manufacturers and medical physicists were refined further, and it was recommended that reference centers should be established as soon as possible. · Constancy testing methods for CT are largely sufficient for lung cancer screening.. · Daily air calibration is recommended to ensure consistent image quality.. · Anthropomorphic phantoms are not currently required for quality assurance.. · Manufacturers must provide protocols that meet LuKrFrühErkV requirements.. Eßeling R, Konrad M, Prokesch H et al. Requirements for Physico-Technical Quality Assurance in the Framework of Early Detection of Lung Cancer. Rofo 2026; DOI 10.1055/a-2597-0689.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Unclear (checked by an automatic rule)What the rule found: language_in: language=de; title_words=15; title_english_function_words=5; title_english_share=0.3333; title_reads=english; abstract_words=268; abstract_english_function_words=89; abstract_english_share=0.3321; abstract_reads=english; language_check=both_english