Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

High-Throughput Peptide Arrays Identify Potential Diagnostic Autoantibody Signatures in Early-Stage Lung Adenocarcinoma

Rongrong Luo; Pei Zhong; Xiying Li; Juan Cai; Yimin Tao; Bangzhu Xiong; Hancheng Zheng; Zhishang Zhang; Le Min Tang; Jiarui Yao; Yingrui Li; Yuankai Shi; Xiaohong Han (2023). Cancer Epidemiology Biomarkers & Prevention

DOI 10.1158/1055-9965.epi-22-0948

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Early diagnosis is critical to lung adenocarcinoma patients' survival but faces inadequacies in convenient early detection. METHODS: We applied a comprehensive microarray of 130,000 peptides to detect "autoantibody signature" that is autoantibodies binding to mimotopes for early detection of stage 0-I LUAD. Plasma samples were collected from 147 early-stage lung adenocarcinoma (Early-LUAD), 108 benign lung disease (BLD), and 122 normal healthy controls (NHC). Clinical characteristics, low-dose CT (LDCT), and laboratory tests were incorporated into correlation analysis. RESULTS: We identified 143 and 133 autoantibody signatures, distinguishing Early-LUAD from NHC/BLD in the discovery cohort. Autoantibody signatures significantly correlated with age, stage, tumor size, basophil count, and IgM level (P < 0.05). The random forest models based on differential autoantibody signatures displayed AUC of 0.92 and 0.87 to discern Early-LUAD from NHC/BLD in the validation cohort, respectively. Compared with LDCT, combining autoantibody signature and LDCT improved the positive predictive value from 50% to 78.33% (P = 0.049). In addition, autoantibody signatures displayed higher sensitivity of 72.4% to 81.0% compared with the combinational tumor markers (cyfra21.1, NSE, SCC, ProGRP) with a sensitivity of 22.4% (P = 0.000). Proteins matched by differential peptides were enriched in cancer-related PI3K/Akt, MAPK, and Wnt pathways. Overlaps between matched epitopes and autoantibody signatures illustrated the underlying engagement of autoantibodies in immune recognition. CONCLUSIONS: Collectively, autoantibody signatures identified by a high-throughput peptide microarray have the potential to detect Early-LUAD, which could assist LDCT to better diagnose Early-LUAD. IMPACT: Novel sensitive autoantibody signatures can adjuvant LDCT to better diagnose LUAD at very early stage.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=1; title_english_share=0.0714; title_reads=not_english; abstract_words=248; abstract_english_function_words=66; abstract_english_share=0.2661; abstract_reads=english; language_check=metadata_listed