Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Self-Supervised Low-Dose CT Denoising via Global Patch Matching and Diffusion Refinement

Boheng Tan; Jun Chen; Xuan Liu; Shan Tan (2025). IEEE International Conference on Bioinformatics and Biomedicine (BIBM)

DOI 10.1109/bibm66473.2025.11356644

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Supervised deep denoising methods have significantly advanced low-dose computed tomography (CT) denoising but require paired clean-noisy samples that are often unavailable in clinical applications. Current most self-supervised methods are motivated by the Noise2Noise framework and achieve successful low-dose CT denoising based on massive adjacent low-dose CT slices. However, these methods are limited by slice-similarity necessity with small slice spacing. Large slice spacing with spatial misalignment brings inaccurate predictions of denoising results, necessitating more general method. To this end, we propose Global Patch Matching-Diffusion Refinement method that constructs global volume similar images for self-supervised optimization, followed by the perceptual refinement from diffusion models, termed GPM-DR. Our approach extracts global similar patches from CT sequences via mask similarity and$\mathrm{L}^{2}$norm-based sliding window matching, which enriches the training data diversity. Subsequently, the denoised CT images are incorporated into diffusion models conditioned on constructed noisy CT images to further refine the perceptual image quality. The proposed GPM-DR effectively mitigates low-dose CT image noise while addressing discrepancies between slices with powerful generative ability. The results demonstrate that our method outperforms representative self-supervised method. Extensive experiments demonstrate its exceptional denoising performance with few original low-dose CT slices.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=1; title_english_share=0.0769; title_reads=not_english; abstract_words=208; abstract_english_function_words=47; abstract_english_share=0.2260; abstract_reads=english; language_check=metadata_listed