Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diagnostic performance of advanced modeled iterative reconstruction applied images for detecting urinary stones on submillisievert low-dose computed tomography

Ju Hee Ahn; Seung Ho Kim; Seung Jin Kim; In Chul Nam; Sung Jae Lee; Seong Yong Pak (2017). Acta Radiologica

DOI 10.1177/0284185117738548

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background Repeated computed tomography (CT) scans may be an issue in young adults with urinary stones. Therefore, it is important to know how far the dose can be reduced while maintaining the diagnostic performance. Purpose To generate a hypothesis that it is feasible to decrease the radiation dose to a sub-millisievert (mSv) level with the addition of advanced modeled iterative reconstruction (ADMIRE) while maintaining the sensitivity to standard-dose CT (SDCT) for the detection of urinary stones. Material and Methods Ninety-two consecutive patients with urinary stones underwent non-enhanced CT that consisted of standard (120 kVp, 200 mAs) and lose-dose (LDCT) (80 kVp, 60 mAs). The LDCT images were reconstructed separately with five different strengths of ADMIRE (hereafter, S1-S5) and filtered back projection (FBP). Two blinded radiologists independently recorded a number of urinary stones in the six LDCT datasets and SDCT. The sensitivity of each set for detecting urinary stones was compared using the McNemar test. Results A total of 240 urinary stones were analyzed. The sensitivities of the six LDCT datasets showed no difference (FBP, S1-S5, for reader 1: 78%, 79%, 79%, 80%, 80%, and 80%; for reader 2: 64%, 63%, 64%, 64%, 65%, and 66%, P > 0.05, respectively), which were lower than those of SDCT for both readers (reader 1: 88%; reader 2: 81%, P < 0.0001, respectively). Conclusion Despite the addition of ADMIRE, it may not be feasible to decrease the radiation dose to a sub-mSv level while maintaining the sensitivity to SDCT for the detection of urinary stones.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=232; abstract_english_function_words=87; abstract_english_share=0.3750; abstract_reads=english; language_check=metadata_listed