Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Evaluation of Low-dose Computed Tomography Images Reconstructed Using Artificial Intelligence-based Adaptive Filtering for Denoising: A Comparison with Computed Tomography Reconstructed with Iterative Reconstruction Algorithm

Suyash Kulkarni; Vasundhara Patil; Aniruddha Nene; Nitin Shetty; Amitkumar Choudhari; Akansha Joshi; CS Pramesh; Akshay Baheti; Kalpesh Mahadik (2025). Journal of Medical Physics

DOI 10.4103/jmp.jmp_115_24

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Purpose: Awareness of radiation-induced risk led to the development of various dose optimization techniques in iterative reconstruction (IR) algorithms and deep learning algorithms to improve low-dose image quality. PixelShine (PS) by AlgoMedica Inc., USA, is a vendor-neutral deep learning denoising tool for low-dose studies, and this study analyzed its images. Aim: The aim of this study was to assess the diagnostic value of PS-reconstructed images obtained at various low doses (LDs). Materials and Methods: A retrospective study qualitatively and quantitatively evaluated the low-dose PS-reconstructed images by comparing them with other reconstruction methods and standard dose (SD) images. A total of 85 cases were evaluated, of which 32 cases were scanned on a scanner with filtered back projection (FBP) reconstruction with LD scans performed at 70%–50% of SD. The remaining 53 cases were performed on the scanner with IR, 35 of them had LD scan at 50% of SD and 18 cases had LD scan at 33% of SD. Results: Qualitative image analysis – The quality of low-dose images with PS and IR was almost equivalent in terms of noise magnitude and texture at 50% dose, and PS images were slightly better at 33% dose reduction. Quantitative image analysis – Low-dose PS-reconstructed images and low-dose iterative reconstructed images had similar contrast-to-noise ratio at 50% dose reduction; however, at 33% of the SD, PS-reconstructed images outperformed. The SD FBP images were equivalent to LD PS-reconstructed images (50% dose reduction). Conclusions: Artificial intelligence-based denoising algorithms produce similar images as IR at 50% dose reduction and outperform it at 33% of the SD.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=26; title_english_function_words=5; title_english_share=0.1923; title_reads=english; abstract_words=259; abstract_english_function_words=87; abstract_english_share=0.3359; abstract_reads=english; language_check=metadata_listed