Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A Mean-Reverting Conditional Diffusion Model for Pulmonary LDCT Image Denoising

Xianfeng Zeng; Sangdae Kim (2026). IEEE Access

DOI 10.1109/access.2026.3715887

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose CT (LDCT) plays a critical role in the early screening of lung cancer. However, the inherent high noise levels and severe artifacts in LDCT images significantly hinder the recognition of fine anatomical structures, and existing denoising methods often struggle to balance noise suppression with structural fidelity. In this paper, we propose AWA-Diff, a conditional diffusion-based denoising method that integrates a mean-reverting stochastic differential equation (SDE) with an adaptive attention mechanism. The core idea is twofold: (1) we replace the standard SDE in the forward diffusion with a mean-reverting SDE, so that the forward noising process performs controlled perturbations around the conditional LDCT image rather than diffusing toward an unrelated fixed prior. This yields a more controllable trajectory for reverse denoising and reduces the risk of structural drift; (2) we design a timestep-aware adaptive weight-fused spatial-channel attention module (ASCAM) for the denoising network. By introducing explicit timestep modulation, ASCAM dynamically adjusts the contribution weights of channel attention and spatial attention during feature fusion. Consequently, the model relies more on global statistics under strong noise and progressively shifts its focus to local details as the noise decreases. We trained and tested the proposed method on the public Mayo 2016 dataset at a 25% dose level and compared it with RED-CNN, CTformer, DDPM, Cold Diffusion, CoreDiff, Dn-Dp, and other baselines. We further evaluated its generalization on the Mayo 2020 dataset at a 10% dose level. Experimental results show that AWA-Diff outperforms the compared methods in terms of PSNR, SSIM, RMSE, and VIF. Full-test-set ablation studies confirm the individual and joint contributions of the mean-reverting SDE, conditional input, and ASCAM. Additional objective diagnostic-quality metrics, residual/uncertainty analysis, and computational profiling further characterize the structural fidelity and computational cost of the method.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=11; title_english_function_words=2; title_english_share=0.1818; title_reads=english; abstract_words=297; abstract_english_function_words=90; abstract_english_share=0.3030; abstract_reads=english; language_check=metadata_listed