Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

ARC-UNet: An Attention–Residual Convolutional U-Net for Low-Dose CT Image Denoising

Rongni Zhou; Guizhong Fang (2026). IEEE International Conference on Power, Intelligent Computing and Systems (ICPICS)

DOI 10.1109/icpics70703.2026.11761343

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) reduces radiation hazards faced by patients, however, there is also severe quantum noise which blurs the diagnostic information of the image itself. In order to restore diagnostic-quality scans, this study proposes an Attention-Residual Convolutional U-Net (ARC-UNet) framework. Firstly, in terms of data preparation, in this experiment, 1,383 spatially aligned quarter-dose and full-dose CT pairs from the 2016 AAPM-Mayo Clinic dataset were taken as the research object, raw files were converted to Hounsfield Units in the range of [-1000, 1000], normalized to [0, 1], resized to size of 256×256 pixels. Secondly, the ARC-UNet replaced the traditional convolutional layers with ResNet blocks to avoid gradient degradation problems. Besides, a Convolutional Block Attention Module (CBAM) combined with Attention Gates (AGs) constituted the dual attention mechanism in the ARC-UNet model, which could adaptively refine features and selectively filter noisy spatial representations. Finally, optimization was realized through a customized hybrid loss function composed of Mean Absolute Error and Structural Similarity Index Measure (SSIM). Through quantitative evaluation, PSNR of ARC-UNet reached 37.8037 dB, SSIM was 0.9259, RMSE was 0.0130. Compared with CNN baseline, PSNR increased by 2.4166 dB on average. It successfully restored subtle tissue variations and sharp organ contours. Thus, it could be seen that the ARC-UNet provides a robust, high-fidelity solution for LDCT enhancement, significantly mitigating radiation risks while preserving essential anatomical structures for precise clinical assessments.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=229; abstract_english_function_words=68; abstract_english_share=0.2969; abstract_reads=english; language_check=metadata_listed