Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

S135 Comparing changes in solid component diameter and mass for detecting invasive adenocarcinoma in sub-solid pulmonary nodules (SSNs): the SUMMIT study

Chuen Ryan Khaw; Daryl Cheng; Andrew W. Creamer; Helen Hall; Amyn Bhamani; Priyam Verghese; Ruth Prendecki; Monica L.L. Mullin; Jennifer L. Dickson; Carolyn Horst; Sophie Tisi; Adam Pennycuick; Hugh Selway‐Clarke; Zoe Frazer; Kate Davies; Charlotte Percival; Kylie Gyertson; Anne-Marie Hacker; L Hughes; Sevasti Galani; Laura Farrelly; J McCabe; William Martin Ricketts; Joseph Jacob; Allan K. Hackshaw; Arjun Nair; Sam M. Janes (2024). Thorax

DOI 10.1136/thorax-2024-btsabstracts.140

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Introduction and Objectives Evolution in size, density and morphology of sub-solid pulmonary nodules (SSNs) instigate conclusive management as they herald invasive adenocarcinoma (IA). Solid component diameter (SCD) correlates with the degree of invasion, but changes in SCD density and overall nodule mass (the product of nodule volume and density), are under-studied. We compare the accuracy of recommended thresholds (alone and in combination) for absolute SCD, and changes in SCD and mass, for detecting IA in SSNs. Methods Participants with persistent SSNs were monitored with Low-Dose Computed Tomography (LDCT) in the SUMMIT LDCT lung screening study (NCT03934866). Semi-automated segmentation provided volume and SCD measurements, and nodule mass (mg) derived by [volume (mm³) × (Hounsfield Units + 1000)/1000]. Changes in SCD and mass from initial detection to either the last study scan or the final scan before intervention were compared against recommended thresholds of absolute SCD ≥ 8mm, SCD change ≥ 2mm and mass change ≥ 30%. Sensitivity, specificity, and AUROC for histologically proven IA were calculated. No proven IA was defined as absence of a lung cancer diagnosis in national cancer registries. Results In 590 participants with 813 SSNs [559 (68.8%) non-solid, 254 (31.2%) part-solid, median overall diameter 10.2mm (IQR 7.6–14mm), follow-up 4.3 years (IQR 4.0–4.5years)], 54 (6.6%) had IA, and 759 (93.4%) had no proven IA. SCD change ≥2mm and mass change ≥30% achieved sensitivities of 50% (95%CI 36–64%) and 52% (95%CI 38–66%) respectively, but SCD change was more specific (table 1). The absolute SCD threshold of ≥8mm improved sensitivity to 63% (95%CI 49–76%); combining it with mass change ≥30% or SCD change ≥2mm for cases where SCD <8mm, further enhanced sensitivity to 87% and 76% respectively. Only the combination of SCD ≥8mm and SCD change ≥2mm retained high specificity (92% (95%CI 90–94%)) and had the highest AUROC (0.84). Conclusion A combined strategy using SCD ≥ 8mm and SCD change ≥ 2mm in nodules under the 8mm threshold potentially provides the best balance of sensitivity, specificity and accuracy for diagnosing invasive adenocarcinoma in SSNs. While combining an SCD 8mm threshold with mass change ≥ 30% optimised sensitivity, this came at the expense of specificity.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=5; title_english_share=0.2273; title_reads=english; abstract_words=325; abstract_english_function_words=101; abstract_english_share=0.3108; abstract_reads=english; language_check=metadata_listed