Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Prediction of Hyperinflation From Low Dose Computed Tomography

Irtza Sharif; B. Valdivia; Maximo E. Lama; Fortune O. Alabi; D. Sharif; A. Rubbo (2025). American Journal of Respiratory and Critical Care Medicine

DOI 10.1164/ajrccm.2025.211.abstracts.a6893

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract IntroductionAccurate identification of emphysema patients with hyperinflated lungs is crucial for determining candidacy for endoscopic lung volume reduction (ELVR) procedures. Traditionally, Total Lung Capacity (TLC) is measured through plethysmography to assess lung hyperinflation. Low-Dose Computed Tomography (LDCT), used as a screening tool for lung cancer, is performed in the same general population of patients who could potentially benefit from ELVR. This study evaluates the sensitivity and specificity of LDCT in identifying patients with elevated TLC (>100% predicted), which may indicate suitability for ELVR procedures. MethodsThis is a retrospective study in which paired TLC measurements from LDCT and plethysmography were analyzed from a single-center patient cohort. Plethysmography was used as the reference standard for hyperinflation assessment. Sensitivity and specificity analyses were conducted using custom-written software to determine LDCT's ability to detect patients with TLC > 100% predicted, identifying potential candidates for ELVR. ResultsA total of 75 charts were reviewed, of which 49 met the inclusion criteria based on both LDCT and plethysmography being performed within a month of each other. Of these, 17 had an elevated TLC on plethysmography, and 11 on LDCT. True positives for air trapping were 9 and true negatives were 30. False positives were 2 and false negatives were 8. The sensitivity of LDCT in predicting a high TLC was 52.9%, and specificity was 93.8%. The correlation coefficient between TLC measured by plethysmography and by LDCT is 0.66. DiscussionThis study highlights the potential value of LDCT as a practical screening tool for identifying emphysema patients with hyperinflation who may benefit from ELVR procedures. While the sensitivity of LDCT in predicting hyperinflation was moderate, the specificity was high, indicating that LDCT can reliably rule in patients with significant hyperinflation. This specificity is especially valuable because it allows clinicians to confidently identify patients with air trapping who could be considered for ELVR, a procedure that can significantly improve symptoms in selected patients. LDCT is already widely used in this patient population for lung cancer screening, meaning it has the advantage of being readily available and already used. Adding screening for hyperinflation without requiring additional procedures or equipment can bring benefit without added risks. Standardizing an air-trapping metric in LDCT, as demonstrated by this study's software, could streamline identification of suitable ELVR candidates in clinical settings.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=8; title_english_function_words=2; title_english_share=0.2500; title_reads=english; abstract_words=369; abstract_english_function_words=144; abstract_english_share=0.3902; abstract_reads=english; language_check=metadata_listed