Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Applying CT texture analysis to determine the prognostic value of subsolid nodules detected during low-dose CT screening

Qi Sun; Yao Huang; Juan Wang; Shijun Zhao; Linhua Zhang; Wei Tang; Ning Wu (2018). Clinical Radiology

DOI 10.1016/j.crad.2018.07.103

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

AIM: To analyse subsolid nodules (SSNs) detected during low-dose (LD) computed tomography (CT) screening and investigated whether CT texture analysis parameters can predict the malignancy and growth trends of GGNs. MATERIALS AND METHODS: In this retrospective study, 89 SSNs were detected in 86 LDCT screening participants, including 42 pure ground-glass nodules (GGNs) and 47 part-solid GGNs. In these participants, 28 SSNs were diagnosed as lung cancer at histopathology, and 61 SSNs from participants who underwent at least two LDCT imaging studies. All nodules were divided into three groups: cancer group, growth group, and non-growth group. The nodule size, volume, attenuation, volume doubling time (VDT), and texture parameters (mean value, uniformity, entropy and energy) were assessed, respectively. RESULTS: The entropy of the cancer group was significantly higher than that of the growth and non-growth groups (pure GGNs: p=0.009, 0.001; part-solid GGNs: p=0.012, 0.004). The energy of the cancer group was significantly lower than that of the other groups (pure GGNs: p=0.043, 0.021; part-solid GGNs: p=0.001, 0.002). A good positive correlation was found between uniformity and VDT (p=0.022). CONCLUSION: Different CT texture parameters show good predictive value for SSNs detected at LDCT screening: the entropy and energy differences between malignant pulmonary nodules and others could be a helpful quantitative index to predict the malignancy of SSNs. Uniformity could be used to predict the growth probability of pure GGNs at baseline to pay more attention to these nodules. Moreover, the follow-up and treatment plan could be more targeted.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=243; abstract_english_function_words=80; abstract_english_share=0.3292; abstract_reads=english; language_check=metadata_listed