Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction

Yoshifumi Noda; Yukako Iritani; Nobuyuki Kawai; Toshiharu Miyoshi; Takuma Ishihara; Fuminori Hyodo; Masayuki Matsuo (2021). Abdominal Radiology

DOI 10.1007/s00261-021-03111-x

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To evaluate image quality, image noise, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic low-dose computed tomography (LDCT) reconstructed using deep learning image reconstruction (DLIR) and compare with those of images reconstructed using hybrid iterative reconstruction (IR). METHODS: Our institutional review board approved this prospective study. Written informed consent was obtained from all patients. Twenty-eight consecutive patients with PDAC undergoing chemotherapy (14 men and 14 women; mean age, 68.4 years) underwent pancreatic LDCT for therapy evaluation. The LDCT images were reconstructed using 40% adaptive statistical iterative reconstruction-Veo (hybrid-IR) and DLIR at medium and high levels (DLIR-M and DLIR-H). The image noise, diagnostic acceptability, and conspicuity of PDAC were qualitatively assessed using a 5-point scale. CT numbers of the abdominal aorta, portal vein, pancreas, PDAC, background noise, signal-to-noise ratio (SNR) of the anatomical structures, and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative and quantitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H images. RESULTS: CT dose-index volumes and dose-length product in pancreatic LDCT were 2.3 ± 1.0 mGy and 74.9 ± 37.0 mGy•cm, respectively. The image noise, diagnostic acceptability, and conspicuity of PDAC were significantly better in DLIR-H than those in hybrid-IR and DLIR-M (all P < 0.001). The background noise was significantly lower in the DLIR-H images (P < 0.001) and resulted in improved SNRs (P < 0.001) and CNR (P < 0.001) compared with those in the hybrid-IR and DLIR-M images. CONCLUSION: DLIR significantly reduced image noise and improved image quality in pancreatic LDCT images compared with hybrid-IR.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=259; abstract_english_function_words=70; abstract_english_share=0.2703; abstract_reads=english; language_check=metadata_listed