Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Reduced computed tomography radiation dose in HIV-related pneumonia: effect on diagnostic image quality

Elisa Busi Rizzi; Vincenzo Schininà; Francesco Paolo Gentile; Corrado Bibbolino (2007). Clinical Imaging

DOI 10.1016/j.clinimag.2006.09.026

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: The objective of this study was to compare the diagnostic quality of low-dose computed tomography (CT) with that of standard-dose chest CT in the diagnosis of infectious lung diseases. MATERIALS AND METHODS: Thirty chest CT scans [high-resolution computed tomography (HRCT), 15; spiral CT, 15] were performed in HIV-positive patients with an infectious lung disease. Two additional slices were obtained at two lower exposures (HRCT, 120 kV/70 mAs and 120 kV/50 mAs; spiral CT, 100 kV/56 mAs and 100 kV/40 mAs) after chest routine CT. Observers compared the quality of the images obtained at different parameters and image noise. Objective evaluation of image noise was also made. RESULTS: Diagnostic image quality was excellent in 93% of the low-dose HRCT scans and in 86% of the low-dose spiral CT scans, rates that are always acceptable in any case. Significant differences were found in noise levels between the low-dose and reference scans; however, artifacts did not compromise detection of abnormalities. In HRCT, a mean reduction of 77% from the standard technique to the low-dose scan is possible in total and in lung effective doses. In spiral CT, this reduction is lower at 71%. These values can reach a further reduction with ultra-low-dose imaging (84% in HRCT and 80% in spiral CT). CONCLUSIONS: Chest CT image quality appears to be adequate to evaluate pulmonary infectious diseases, even with an effective reduction in radiation dose. Standard-dose CT with a higher patient effective dose may be appropriate for selected cases.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=244; abstract_english_function_words=85; abstract_english_share=0.3484; abstract_reads=english; language_check=metadata_listed