Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Interstitial lung abnormalities in the Queensland Lung Cancer Screening Study: prevalence and progression over 2 years of surveillance

John A. Mackintosh; Henry Marshall; R. Slaughter; Taryn L. Reddy; Ian A. Yang; Rayleen Bowman; Kwun Meng Fong (2018). Internal Medicine Journal

DOI 10.1111/imj.14148

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: We report the prevalence and progression of incidentally detected interstitial lung abnormalities (ILA) in the Queensland Lung Cancer Screening Study cohort. METHODS: About 256 volunteers aged 60-74, with ≥30 pack years smoking history and forced expiratory volume in 1 s (FEV1) ≥50% predicted underwent low-dose computed tomography (CT) chest screening. Electronic search of baseline (T0) and 2-year follow-up (T2) CT reports identified candidate cases using Fleischner Society interstitial terminology. Candidate CT were reviewed in a randomised order by two experienced radiologists and a senior respiratory medicine trainee blinded to the existing reports. Scans were evaluated for the presence and extent of ILA using an in-house score, and graded for progression. RESULTS: ILA were detected in 20/256 baseline cases (7.8%) with no incident cases detected at T2 surveillance imaging. Of these 20 cases, 9 (45%) had reticulation, 18 (90%) had ground glass change, 1 had traction bronchiectasis and 1 had randomly distributed nodularity. Seven cases with ground glass changes also had areas of reticulation, and only two had reticulation alone. All ILA were graded as minor except for traction bronchiectasis, which was moderate. Only one case progressed on T2 imaging. ILA were associated with the presence of auscultatory crackles (50% vs 11.6%, P = 0.001) and a lesser degree of emphysema (mean % volumetric emphysema 6.7% vs 9.8%, P = 0.009). No relationship was observed between baseline and serial lung function parameters. CONCLUSION: ILA are frequent incidental findings in lung cancer screening. In the majority of cases these abnormalities do not appear to change significantly over a 2-year period of surveillance.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=5; title_english_share=0.2941; title_reads=english; abstract_words=241; abstract_english_function_words=75; abstract_english_share=0.3112; abstract_reads=english; language_check=metadata_listed