Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Variability Among Radiologists in Interpreting Low-Dose CT Lung Cancer Screens
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Lung cancer screening (LCS) with low-dose CT (LDCT) reduces lung cancer mortality, but false-positive tests remain a concern. Radiologist variability in interpreting LDCT scans may contribute to higher false-positive rates (FPRs). METHODS: Radiologists were identified from the LCS registry maintained by the ACR. Registry data were merged with Medicare files to create an LCS registry-Medicare database. Radiologists with ≥50 baseline or ≥50 postbaseline LDCT screens in the database were included in the analysis. The sensitivity and FPR were defined as the proportion of positive (Lung CT Screening Reporting and Data System 3-4) screens among those with and without a lung cancer diagnosis, respectively. Distributions, including median and interquartile range, of radiologists' FPRs were evaluated based on observed data and mixed-effects models, in which the radiologist was the random effect. Sensitivity was computed on an aggregate level based on radiologists' FPR quartiles. RESULTS: In all, 1,130 radiologists read ≥50 baseline screens, and 935 read ≥50 postbaseline screens. Median (interquartile range) FPR for baseline screens was 15.9% (11.3%-21.8%) and 16.3% (11.8%-21.8%) based on observed data and the mixed-effects model, respectively. Corresponding values for postbaseline screens were 8.5% (5.7%-12.8%) and 8.8% (6.3%-11.8%). Sensitivity increased significantly with radiologist FPR quartile for baseline and postbaseline screens. For baseline screens, radiologists in the lower two FPR quartiles had aggregate FPR and sensitivity of 10.9% and 89.6%, respectively, versus 24.1% and 94.4% for radiologists in the upper two quartiles. CONCLUSIONS: Variability in radiologists' FPRs with LDCT screening was high. Higher FPRs were associated with increased sensitivity rates.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=11; title_english_function_words=2; title_english_share=0.1818; title_reads=english; abstract_words=238; abstract_english_function_words=80; abstract_english_share=0.3361; abstract_reads=english; language_check=metadata_listed