Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Perinodular Parenchymal Features Improve Indeterminate Lung Nodule Classification

A.H.P. Masquelin; Thayer Alshaabi; Nick Cheney; Raúl San Jośe Estépar; Jason H. T. Bates; C. Matthew Kinsey (2022). Academic Radiology

DOI 10.1016/j.acra.2022.07.001

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Radiomics, defined as quantitative features extracted from images, provide a non-invasive means of assessing malignant versus benign pulmonary nodules. In this study, we evaluate the consistency with which perinodular radiomics extracted from low-dose computed tomography images serve to identify malignant pulmonary nodules. MATERIALS AND METHODS: Using the National Lung Screening Trial (NLST), we selected individuals with pulmonary nodules between 4mm to 20mm in diameter. Nodules were segmented to generate four distinct datasets; 1) a Tumor dataset containing tumor-specific features, 2) a 10 mm Band dataset containing parenchymal features between the segmented nodule boundary and 10mm out from the boundary, 3) a 15mm Band dataset, and 4) a Tumor Size dataset containing the maximum nodule diameter. Models to predict malignancy were constructed using support-vector machine (SVM), random forest (RF), and least absolute shrinkage and selection operator (LASSO) approaches. Ten-fold cross validation with 10 repetitions per fold was used to evaluate the performance of each approach applied to each dataset. RESULTS: With respect to the RF, the Tumor, 10mm Band, and 15mm Band datasets achieved areas under the receiver-operator curve (AUC) of 84.44%, 84.09%, and 81.57%, respectively. Significant differences in performance were observed between the Tumor and 15mm Band datasets (adj. p-value <0.001). However, when combining tumor-specific features with perinodular features, the 10mm Band + Tumor and 15mm Band + Tumor datasets (AUC 87.87% and 86.75%, respectively) performed significantly better than the Tumor Size dataset (66.76%) or the Tumor dataset. Similarly, the AUCs from the SVM and LASSO were 84.71% and 88.91%, respectively, for the 10mm Band + Tumor. CONCLUSIONS: The combined 10mm Band + Tumor dataset improved the differentiation between benign and malignant lung nodules compared to the Tumor datasets across all methodologies. This demonstrates that parenchymal features capture novel diagnostic information beyond that present in the nodule itself. (data agreement: NLST-163).

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=8; title_english_function_words=0; title_english_share=0.0000; title_reads=not_english; abstract_words=291; abstract_english_function_words=89; abstract_english_share=0.3058; abstract_reads=english; language_check=metadata_listed