Low-dose CT coronary angiography for the prediction of myocardial ischaemia

Paul Stolzmann; Olivio F. Donati; Hans Scheffel; Naim Azemaj; Stephan Baumueller; André Plass; Sebastian Kozerke; Sebastian Leschka; Jürg Grünenfelder; Peter Boesiger; Borut Marinček; Hatem Alkadhi (2009). European Radiology

DOI 10.1007/s00330-009-1536-x

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The purpose of this study was to prospectively determine the accuracy of low-dose computed tomography coronary angiography (CTCA) for the diagnosis of functionally relevant coronary artery disease (CAD) using cardiac magnetic resonance (CMR) as a standard of reference. Forty-one consecutive patients (age 64 +/- 10 years) underwent k-space and time broad-use linear acquisition speed-up technique accelerated CMR (1.5 T) and dual-source CTCA using prospective electrocardiography gating within 1 day. CTCA lesions were analysed and diameter stenoses of more than 50% and more than 75% were compared with CMR findings taken as the reference standard for assessing the functional relevance of CAD. CMR revealed perfusion defects in 21/41 patients (51%). A total of 569 coronary segments were analysed with low-dose CTCA. The image quality of low-dose CTCA was diagnostic in 566/569 segments (99.5%) in 39/41 patients (95%). Low-dose CTCA revealed stenoses of more than 50% in 58/123 coronary arteries (47.2%) in 24/41 patients (59%) and more than 75% stenoses in 46/123 coronary arteries (37.4%) in 23/41 patients (56%). Using a greater than 50% diameter stenosis, low-dose CTCA yielded the following per artery sensitivity, specificity, positive and negative predictive values, and accuracy for the detection of perfusion defects: 89%, 79%, 72%, 92% and 83%, respectively. Low-dose CTCA is reliable for ruling out functionally relevant CAD, but is a poor predictor of myocardial ischaemia.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=11; title_english_function_words=3; title_english_share=0.2727; title_reads=english; abstract_words=202; abstract_english_function_words=66; abstract_english_share=0.3267; abstract_reads=english; language_check=metadata_listed