Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Can intraoperative endoscopic evaluation replace postoperative low-dose CT for assessing the stone-free status in vacuum-assisted dedusting lithotripsy

Qi Liu; Junkai Huang; Jian Li; Xuanhao Zhang; Yue Hong Zheng; Chunyu Liu; Haijie Xie (2025). World Journal of Urology

DOI 10.1007/s00345-025-05911-y

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To compare the diagnostic accuracy of intraoperative endoscopic assessment with postoperative low-dose computed tomography (LDCT) for determining stone-free status (SFS) following retrograde vacuum-assisted dedusting lithotripsy (VADL) using a tip-flexible vacuum-assisted suction ureteral access sheath (tFVS-UAS) and evaluate the feasibility of replacing routine LDCT with intraoperative evaluation. METHODS: This single-center retrospective study analyzed 1,105 patients undergoing unilateral VADL (December 2022-December 2024). All VADL procedures were performed retrograde using tFVS-UAS. Postoperative LDCT on day 30 served as the reference standard. Agreement between intraoperative endoscopic assessment and LDCT was evaluated using McNemar's test and Kappa statistics. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. RESULTS: The overall stone-free rate (SFR) was 83.35% (89.89% for stones ≤ 20 mm; 63.50% for stones > 20 mm). Intraoperative assessment demonstrated high specificity (98.70%, 95% CI: 97.80-99.60%) but low sensitivity (43.48%, 95% CI: 36.35-50.61%), with an NPV of 89.73% and PPV of 86.96%. Subgroup analysis revealed stronger agreement for stones ≤ 20 mm (Kappa = 0.61, NPV = 94.40%) compared to stones > 20 mm (Kappa = 0.40, sensitivity = 40.00%)(Bonferroni-adjusted α = 0.025). CONCLUSION: Intraoperative endoscopic assessment during VADL reliably confirms SFS for stones ≤ 20 mm, potentially reducing the utilization of postoperative LDCT in low-risk patients when SFS is endoscopically verified. However, LDCT remains essential for stones > 20 mm or high-risk scenarios due to limited sensitivity. Clinical implementation requires risk stratification and shared decision-making.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=4; title_english_share=0.2000; title_reads=english; abstract_words=215; abstract_english_function_words=46; abstract_english_share=0.2140; abstract_reads=english; language_check=metadata_listed