Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A plasma cell-free DNA methylation classifier for non-invasive lung nodule malignancy assessment

xin wang; Jiayi Li; Lingfeng Bi; Zhixi Su; Zhoufeng Wang; Weimin Li (2025). European Respiratory Journal

DOI 10.1183/13993003.congress-2025.pa5035

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Low-dose computed tomography (LDCT) is currently the recommended screening modality; however, its high false positive rate and reliance on radiologists' subjective judgment limit its widespread clinical application. Biomarker-based approaches utilizing DNA methylation signatures may provide a more accurate method for lung nodule classification and enhance early lung cancer detection. Objective: This study aimed to develop and validate LunaCAM Plus, a non-invasive plasma-based classifier leveraging cfDNA methylation analysis to improve lung nodule malignancy assessment and enhance early-stage lung cancer detection. Methods: A total of 96 patients were enrolled (37 malignant, 29 benign, 30 healthy). Lung cancer and adjacent normal tissues were collected, and epithelial cells were isolated via fluorescence-activated cell sorting (FACS) to minimize interference from immune cells. Genomic DNA was subjected to reduced representation bisulfite sequencing (RRBS), and a set of 539 differentially methylated regions (DMRs) was identified by integrating data from Panseer and LunaCAM databases. The LunaCAM Plus classifier was developed using Methylation Encoding Score (MES) and Normalized Count of Haplotype (nCOH). Model training was conducted using 5-fold cross-validation on a training cohort (160 plasma samples: 80 malignant, 80 benign), followed by validation on an independent test cohort (114 plasma samples: 40 malignant, 74 benign). Results: In the training cohort, LunaCAM Plus achieved AUC = 0.859, specificity = 0.94, sensitivity = 0.56. In the independent test cohort, it maintained strong classification performance (AUC = 0.851, specificity = 0.93, sensitivity = 0.50).

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=217; abstract_english_function_words=51; abstract_english_share=0.2350; abstract_reads=english; language_check=metadata_listed