Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Effect of dual-source cardiac computed tomography on patient radiation dose in a clinical setting: Comparison to single-source imaging

Sandra S. Halliburton; Srikanth Sola; Stacie A. Kuzmiak; Nancy A. Obuchowski; Milind Desai; Scott D. Flamm; Paul Schoenhagen (2008). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2008.09.003

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Dual-source computed tomography (DSCT) was introduced with significant hardware and software changes compared with single-source CT (SSCT), resulting in improved temporal resolution (83 ms) and the potential for improved image quality. The effect of these changes on radiation dose requirements for coronary CT angiography in clinical practice has not been investigated. OBJECTIVE: We evaluated patient radiation dose and image quality of electrocardiogram (ECG)-gated helical techniques, using DSCT compared with SSCT for clinical imaging of the coronary arteries. METHODS: DSCT data from 160 patients were evaluated; 82 patients (DSCT group 1) were imaged with early software, and 78 patients (DSCT group 2) were imaged with a later software version. Patients imaged with SSCT (n = 124) were the control group. Effective radiation dose values were estimated for all patients. Image noise was measured, and image quality was evaluated on a 5-point scale. RESULTS: Effective dose values for DSCT group 2 (11.7 +/- 4.0 mSv) were not different from those for SSCT group (10.9 +/- 2.9 mSv); the highest doses, 13.2 +/- 3.2 mSv, were recorded for DSCT group 1 (P < 0.001). A decrease in image noise was observed for DSCT compared with SSCT (P <or= 0.001) as was an increase in image quality (P < 0.01). With optimized DSCT imaging, lower dose values were associated with (1) shorter scan range, (2) lower maximum tube current, and (3) lower fraction of R-R interval receiving maximum tube current. CONCLUSION: ECG-gated helical DSCT can provide images of the coronary arteries with improved image quality and decreased noise without an increase in radiation dose compared with SSCT in clinical patient groups.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=246; abstract_english_function_words=76; abstract_english_share=0.3089; abstract_reads=english; language_check=metadata_listed