Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automated cardiac chamber segmentation using non-contrast CT images

Qiyu Zhang; Yumeng Zhang; Hamidreza Khodajou-Chokami; Dean P. Nguyen; Dale Black; Wenbo Li; Justin Truong; Sabee Y. Molloi (2025). SPIE Medical Imaging: Computer-Aided Diagnosis

DOI 10.1117/12.3047463

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Accurate assessment of cardiovascular risk using low-dose computed tomography (CT) scans is crucial for managing cardiovascular diseases (CVD), the leading cause of death in the United States. However, automatic segmentation of non-contrast CT images is challenging due to the scarcity of labels and the complexity of manual annotation. Existing segmentation methods primarily focus on contrast-enhanced CT and do not apply to patients with only non-contrast scans. In this study, we address this gap by leveraging a dataset of 55 patients who each underwent both contrast-enhanced and non-contrast ECG-gated CT scans. After co-registering these paired datasets, we transferred labels from contrast-enhanced images to their spatially aligned non-contrast counterparts. Due to limited availability of paired data, we additionally employed a generative adversarial network (GAN) to synthesize non-contrast CT images from the contrast-only scans, thereby expanding our training set. We trained an nnUNet model on the combined real and synthesized non-contrast dataset and incorporated Hausdorff distance (HD) loss to improve boundary delineation. This approach achieved an averaged Dice Similarity Coefficient of 0.89 on non-contrast CT images, with predicted left and right ventricular chamber sizes showing strong correlations (R2 = 0.91) compared to ground truth measurements from contrast-enhanced scans. Notably, the synthesized images further improved segmentation accuracy for the left ventricular chamber. This fully automated method enables precise boundary segmentation and robust, large-scale evaluation of cardiac structures on non-contrast CT scans, thereby facilitating earlier and more effective cardiovascular risk stratification.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=0; title_english_share=0.0000; title_reads=not_english; abstract_words=249; abstract_english_function_words=68; abstract_english_share=0.2731; abstract_reads=english; language_check=metadata_listed