Feasibility of Latest-Generation Cone-Beam CT for Thoracic Imaging: A Pilot Study
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Lung cancer remains the leading cause of cancer-related death worldwide. Low-dose computed tomography (LDCT) is the current gold standard for screening, but radiation exposure remains a concern. Cone-Beam Computed Tomography (CBCT) offers ultra-low-dose acquisition but has not yet been tested for thoracic screening. PURPOSE: To evaluate the feasibility of using a latest-generation CBCT system for thoracic imaging in a lung cancer screening context. MATERIALS AND METHODS: 88 patients, current or former smokers, were retrospectively included. They underwent thoracic CBCT (7 G Dual Energy system, NewTom, Italy) between July 2024 and April 2025 at a preventive health center, with either a standard-dose protocol (n = 48) or a low-dose protocol (n = 40). Two board-certified radiologists independently assessed pulmonary findings and image quality. Radiation doses were compared. Statistical analysis included mixed-effects models and interobserver agreement. RESULTS: The radiation exposure was significantly lower in the low-dose group, with a median cumulative DLP of 42.8 mGy·cm, compared to 107.7 mGy·cm, representing a 2.5-fold reduction in radiation (p<0.001). Nodule detection occurred in 41% of patients overall. Overall image quality was rated good/excellent in 85% (low-dose) vs 83% (standard-dose); Risk Difference (RD) = +2% [IC95% -12; +16], Risk Ratio (RR) = 1.03. Diagnostic confidence was high in 82% vs 83%; RD = -1% [-14; +12], RR = 0.99. Spatial resolution was slightly lower in the low-dose group (OR = 0.51, p = 0.04). Interobserver agreement for nodule detection was substantial across both groups (κ = 0.73-0.83). CONCLUSION: Low-dose CBCT offers substantial radiation dose reduction without compromising diagnostic confidence or interobserver reliability. CBCT may represent a promising, cost-effective alternative or complement to low-dose CT in preventive lung imaging programs, but prospective studies comparing CBCT to LDCT are warranted.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=270; abstract_english_function_words=70; abstract_english_share=0.2593; abstract_reads=english; language_check=metadata_listed