Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Optimization of low-dose lung computed tomography procedures using the detectability index

Elsa Bifano Pimenta Rosa. Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais

DOI 10.11606/t.43.2026.tde-17062026-164249

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Optimizing computed tomography (CT) protocols for lung cancer screening and follow-up requires balancing radiation dose reduction with reliable detection and characterization of pulmonary nodules. This thesis presents the application of a task-based framework for protocol optimization using the detectability index as a quantitative image quality metric. The detectability index integrates the task function, noise power spectrum, and task transfer function, enabling simultaneous assessment of contrast sensitivity, noise texture, and spatial resolution under clinically relevant conditions. Two complementary experimental setups were employed: a geometric phantom and a hybrid anthropomorphic lung phantom designed to reproduce realistic anatomy and lesion characteristics. A broad range of acquisition and reconstruction parameters was evaluated, including dose, reconstruction algorithms, and convolution kernels, across both energy-integrating detector CT and photon-counting CT systems. Detectability increased with dose up to approximately 1 mGy, with the highest values achieved using deep learningbased reconstruction combined with lung kernels. Photon-counting CT with deep learning reconstruction consistently yielded superior detectability and volumetric performance. Lung kernels outperformed soft and high-frequency kernels, particularly under low-dose conditions, where noise amplification degraded task performance. Lesion-dependent effects were observed, with smaller nodules and ground-glass opacities exhibiting lower detectability and higher volumetric variability than larger solid nodules. Noise texture features derived from the noise power spectrum were strongly associated with detectability and segmentation precision, highlighting the importance of texture-aware image quality metrics. A strong inverse relationship was observed between detectability and volumetric variability, demonstrating that improvements in task-based image quality translate directly into more accurate and reproducible volumetric measurements. These findings establish a clinically relevant framework for CT protocol optimization, support the use of anthropomorphic phantoms in image quality assessment, and provide evidence-based guidance for dose reduction strategies that preserve diagnostic performance.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=293; abstract_english_function_words=73; abstract_english_share=0.2491; abstract_reads=english; language_check=metadata_missing