Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Voxel-Sensitive Attention-Based Lattice Structure Residual Network for Low-Dose CT Image Denoising Using Wavelet-Based Structure Loss
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Low-dose computed tomography (LDCT) imaging safeguards patients from potentially harmful X-rays. However, the signal-to-noise ratio (SNR) and computed tomography (CT) image quality deteriorate due to lower X-ray flux in the LDCT imaging modality. The custom design of deep networks with vanilla convolution layers ignores sensitive voxel information. Hence, voxel details for reconstructing low-contrast regions and high-frequency lesion edges may be lost during noise suppression. In addition, existing techniques do not satisfactorily address the problem of adversarial learning-induced structural deformation. This article proposes a LDCT denoising method based on Wasserstein GAN (WGAN) with three novel contributions. First, we introduce a novel build block called a voxel-sensitive attention-based lattice residual block (VSA-LRB). The generator network with stacked VSA-LRB can preserve the long-range pixel dependency while aggregating the voxel-sensitive features extracted along the spatial ($H \times W$) and depthwise (D) directions. Furthermore, we train the proposed denoising network to learn efficient structural features via our proposed wavelet-based structural loss. The error is estimated on the wavelet-domain structural feature space, extracted by a dedicated pretrained CT-specific structure-aware network (CT-SANet). Hence, the wavelet-based loss function effectively mitigates structural distortions. We introduce a differential content loss to improve high-frequency lesion boundaries. The proposed method is validated qualitatively and quantitatively using two publicly available datasets: the “2016 NIH-AAPM-Mayo Clinic LDCT Grand Challenge dataset” and the “Low-dose-CT Image and Projection dataset.” The proposed method demonstrates a superior performance when compared with state-of-the-art techniques.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=19; title_english_function_words=1; title_english_share=0.0526; title_reads=not_english; abstract_words=262; abstract_english_function_words=60; abstract_english_share=0.2290; abstract_reads=english; language_check=metadata_listed