Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol

Davide Ippolito; Luca Riva; Cammillo Talei Franzesi; Andrea De Vito; Cecilia Cangiotti; Andrea Crespi; Rocco Corso; Sandro Sironi (2020). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0000000000000965

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Objective To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. Methods Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. Results In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). Conclusion Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=29; title_english_function_words=5; title_english_share=0.1724; title_reads=english; abstract_words=190; abstract_english_function_words=47; abstract_english_share=0.2474; abstract_reads=english; language_check=metadata_listed