Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
BACKGROUND The aim of this study was to compare the metrics of volume computed tomography index (CTDIvol) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL AND METHODS A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDIvol and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDIvol and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDIvol and SSDEaver (P=0.000). The dispersion degree of the CTDIvol values was greater than that of SSDEaver. Strong positive correlation was shown between CTDIvol and mAs (P=0.000), as well as CTDIvol and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=30; title_english_function_words=7; title_english_share=0.2333; title_reads=english; abstract_words=242; abstract_english_function_words=91; abstract_english_share=0.3760; abstract_reads=english; language_check=metadata_listed