Automatic segmentation and radiomic texture analysis for osteoporosis screening using chest low-dose computed tomography

Yung-Chieh Chen; Yi-Tien Li; Po‐Chih Kuo; Sho‐Jen Cheng; Yi-Hsiang Chung; Duen-Pang Kuo; Cheng‐Yu Chen (2023). European Radiology

DOI 10.1007/s00330-023-09421-6

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: This study developed a diagnostic tool combining machine learning (ML) segmentation and radiomic texture analysis (RTA) for bone density screening using chest low-dose computed tomography (LDCT). METHODS: A total of 197 patients who underwent LDCT followed by dual-energy X-ray absorptiometry were analyzed. First, an autosegmentation model was trained using LDCT to delineate the thoracic vertebral body (VB). Second, a two-level classifier was developed using radiomic features extracted from VBs for the hierarchical pairwise classification of each patient's bone status. All the patients were initially classified as either normal or abnormal, and all patients with abnormal bone density were then subdivided into an osteopenia group and an osteoporosis group. The performance of the classifier was evaluated through fivefold cross-validation. RESULTS: The model for automated VB segmentation achieved a Sorenson-Dice coefficient of 0.87 ± 0.01. Furthermore, the area under the receiver operating characteristic curve scores for the two-level classifier were 0.96 ± 0.01 for detecting abnormal bone density (accuracy = 0.91 ± 0.02; sensitivity = 0.93 ± 0.03; specificity = 0.89 ± 0.03) and 0.98 ± 0.01 for distinguishing osteoporosis (accuracy = 0.94 ± 0.02; sensitivity = 0.95 ± 0.03; specificity = 0.93 ± 0.03). The testing prediction accuracy levels for the first- and second-level classifiers were 0.92 ± 0.04 and 0.94 ± 0.05, respectively. The overall testing prediction accuracy of our method was 0.90 ± 0.05. CONCLUSION: The combination of ML segmentation and RTA for automated bone density prediction based on LDCT scans is a feasible approach that could be valuable for osteoporosis screening during lung cancer screening. KEY POINTS: • This study developed an automatic diagnostic tool combining machine learning-based segmentation and radiomic texture analysis for bone density screening using chest low-dose computed tomography. • The developed method enables opportunistic screening without quantitative computed tomography or a dedicated phantom. • The developed method could be integrated into the current clinical workflow and used as an adjunct for opportunistic screening or for patients who are ineligible for screening with dual-energy X-ray absorptiometry.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=299; abstract_english_function_words=98; abstract_english_share=0.3278; abstract_reads=english; language_check=metadata_listed