Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Simulated Low-Dose Computed Tomography in Oncological Patients

Jin Yamamura; Katharina Tornquist; Ralph Buchert; Joachim Wildberger; H.D. Nagel; Daniela Dichtl; Gerhard Adam; Ulrike Wedegärtner (2010). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0b013e3181c95b67

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: Image quality of chest and abdominal computed tomographic (CT) scans was evaluated at different doses to assess the lowest value of x-ray dose at which the image quality was not being affected. MATERIALS AND METHODS: Using multislice CT (MSCT), 29 patients who submitted to follow-up examinations were examined using a combined MSCT protocol of the chest and the abdomen on 4-raw MSCT (Siemens, Erlangen, Germany). For each examination, approximately 120 mL of contrast agent (Bracco-Altana, Konstanz, Germany) was applied intravenously. The raw data were transferred to an external personal computer equipped with an image reconstruction software (CardioRecon 6; Siemens, Forchheim, Germany) to simulate 5 different dose levels. To simulate them correctly, a milliampere second-dependent noise was added to every image, so that the changes in a current-time product could be imitated. The images were compared in consensus by 2 radiologists who were not informed about the technical scanning parameters, that is, dose parameters, and were graded in 4 different subcategories on a 1-to-5-point scale. For statistical analysis, the Friedman test was used. Additional evaluations for lesions smaller than 1.0 cm were performed and analyzed separately. RESULTS: For image noise, there was a significant change between 40 and 60 mA s. For lesion detection, there was no significant change. The contour of the small objects did not differ between 90, 60, and 40 mA s. However, a dose reduction to 30 mA s had a significant effect. The contrast did not differ between 90, 60, 40, and even down to 30 mA s. Only a maximal dose reduction to 20 mA s had a significant effect on the contrast. The level of noise was most sensitive to the current. Whereas a dose reduction to 60 mA s did not yet have a significant effect, there was a significant increase of noise at 40 mA s. CONCLUSIONS: The MSCT can be applied with a lower dose than that usually selected in examinations at present to follow-up and stage the oncological patients adequately.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=8; title_english_function_words=1; title_english_share=0.1250; title_reads=english; abstract_words=318; abstract_english_function_words=136; abstract_english_share=0.4277; abstract_reads=english; language_check=metadata_listed