Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Development of a 3D-Printed Chest Phantom with Simulation of Lung Nodules for Studying Ultra-Low-Dose Computed Tomography Protocols

Jenna Silberstein; Steven Tran; Yin How Wong; Chai Hong Yeong; Zhonghua Sun (2024). Applied Sciences

DOI 10.3390/app15010309

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

This study aimed to 3D print a patient-specific chest phantom simulating multiple lung nodules to optimise low-dose Computed Tomography (CT) protocols for lung cancer screening. The chest phantom, which was developed from a single patient’s chest CT images, was fabricated using a variety of materials, including polylactic acid (PLA), Glow-PLA, acrylonitrile butadiene styrene (ABS), and polyurethane resin. The phantom was scanned under different low-dose (LDCT) and ultra-low-dose CT (ULDCT) protocols by varying the kilovoltage peak (kVp) and milliampere-seconds (mAs). Subjective image quality of each scan (656 images) was evaluated by three radiologists using a five-point Likert scale, while objective image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Anatomical conformance was assessed by comparing tissue diameters of the phantom and patient scans using Bland–Altman analysis. The phantom’s lung tissue, lung nodules, and diaphragm demonstrated radiation attenuation comparable to patient tissue, as measured in Hounsfield Units (HU). However, significant variations in HU were observed for the skin, subcutaneous fat, muscle, bone, heart, lung vessels, and blood vessels compared to patient tissues, with values ranging from 93.9 HU to −196 HU (p < 0.05). Both SNR and CNR decreased as the effective dose was reduced, with a strong positive linear correlation (r = 0.927 and r = 0.931, respectively, p < 0.001, Jamovi, version 2.3.28). The median subjective image quality score from radiologists was 4, indicating good diagnostic confidence across all CT protocols (κ = −0.398, 95% CI [−0.644 to −0.152], p < 0.002, SPSS Statistics, version 30). An optimal protocol of 80 kVp and 30 mAs was identified for lung nodule detection, delivering a dose of only 0.23 mSv, which represents a 96% reduction compared to standard CT protocols. The measurement error between patient and phantom scans was −0.03 ± 0.14 cm. These findings highlight the potential for significant dose reductions in lung cancer screening programs. Further studies are recommended to improve the phantom by selecting more tissue-equivalent materials.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=312; abstract_english_function_words=89; abstract_english_share=0.2853; abstract_reads=english; language_check=metadata_listed