Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

In vivo deposition study of a new generation nebuliser utilising hybrid resonant acoustic (HYDRA) technology

Philip Chi Lip Kwok; Amarin G. McDonnell; Patricia Tang; Callum Knight; Erin McKay; Sidney P. Butler; Allen Sivarajah; Renée Quinn; Luke Fincher; Effie Browne; Leslie Y. Yeo; Hak‐Kim Chan (2020). International Journal of Pharmaceutics

DOI 10.1016/j.ijpharm.2020.119196

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Conventional nebulisation has the disadvantages of low aerosol output rate and potential damage to macromolecules due to high shear (jet nebulisation) or cavitation (ultrasonic nebulisation). HYDRA (HYbriD Resonant Acoustics) technology has been shown to overcome these problems by using a hybrid combination of surface and bulk sound waves to generate the aerosol droplets. We report the first in vivo human lung deposition study on such droplets. Twelve healthy adult subjects inhaled saline aerosols radiolabelled with technetium-99 m complexed with diethylene triamine penta-acetic acid (99mTc-DTPA). The distribution of the aerosolised droplets in the lungs was imaged by single photon emission computed tomography combined with low dose computed tomography (SPECT/CT). The volume median diameter and geometric standard deviation of the droplets were 1.32 ± 0.027 µm and 2.06 ± 0.040, respectively. The mean delivery efficiency from the nebuliser into the body was 51.2%. About 89.1 ± 4.3% and 2.3 ± 1.4% of the inhaled radiolabelled dose deposited in the lungs and oropharynx, respectively. The deposition was symmetrical and diffusive between the two lungs, with a mean penetration index of 0.82. Thus, the prototype HYDRA nebuliser showed excellent in vivo aerosol deposition performance, demonstrating its potential to be further developed for clinical applications.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=3; title_english_share=0.2000; title_reads=english; abstract_words=189; abstract_english_function_words=65; abstract_english_share=0.3439; abstract_reads=english; language_check=metadata_listed