Low-dose versus standard-dose computed tomography-guided core needle biopsy for lung nodules: a randomized controlled trial

Er-Liang Li; Ai-Li Ma; Tao Wang; Yu-Fei Fu; Han-Yang Liu; Guang-Chao Li (2022). Springer Science and Business Media LLC

DOI 10.21203/rs.3.rs-1438386/v1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Abstract Background To assess relative safety and diagnostic performance for low- and standard-dose computed tomography (CT)-guided core needle biopsy (CNB) for lung nodules (LNs). Materials and Methods This is a prospective randomized controlled trial (RCT) from a single-center. From June 2020 to December 2020, consecutive patients with LNs were randomly assigned into low- or standard-dose groups. The primary outcome was diagnosis accuracy, while secondary outcomes encompassed technical success, diagnostic yield, operative time, radiation dose, and CNB-related complications. This RCT was listed within ClinicalTrials.gov (NCT04217655), registered 3 January 2020. Results A total of 200 patients were randomly assigned to low-dose (n = 100) and standard-dose (n = 100) groups. All patients achieved technical success of CT-guided CNB and the definite final diagnoses. No significant difference was found for operative times (n = 0.231) between 2 groups. The mean dose-length product was markedly reduced within low-dose group in comparison to standard-dose group (34.6 ± 11.1 vs. 351.4 ± 107.4 mGy-cm, P < 0.001). Within low-dose group, the diagnostic yield, sensitivity, specificity, and diagnosis accuracy were 68%, 91.5%, 100%, and 94%, respectively. Within standard-dose group, the diagnostic yield, sensitivity, specificity, and diagnosis accuracy were 65%, 88.6%, 100%, and 92%, respectively. There were no significances in diagnostic yield (P = 0.653) and diagnostic accuracy (P = 0.579) between 2 groups. No significant differences within rates of pneumothorax (P = 0.836) and lung hemorrhage (P = 0.744) between 2 groups were observed. Conclusions Compared with standard-dose CT-guided CNB for LNs, low-dose CT can significantly reduce radiation dose, while yield comparable safety and diagnostic accuracy.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=18; title_english_function_words=2; title_english_share=0.1111; title_reads=english; abstract_words=240; abstract_english_function_words=66; abstract_english_share=0.2750; abstract_reads=english; language_check=metadata_missing