Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Deep learning–based super-resolution ultrashort echo time MRI for pulmonary nodule detection and longitudinal assessment in emphysema
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
PURPOSE: This study aimed to evaluate the performance of deep learning-based super-resolution ultrashort echo time magnetic resonance imaging (SR-UTE MRI) for the detection of pulmonary nodules and the reliability of longitudinal nodule size assessment compared with conventional ultrashort echo time (UTE) in patients with emphysema. MATERIALS AND METHODS: This prospective study included 127 patients with emphysema and pulmonary nodules who underwent chest low-dose computed tomography (LDCT) and UTE MRI. SR-UTE images were reconstructed using a deep learning-based algorithm. Pulmonary nodule detection performance, size measurement accuracy, and longitudinal reproducibility were assessed using LDCT as the reference standard. Patients were stratified according to CT-derived emphysema severity quantified by low-attenuation area percentage (LAA%). Objective image quality metrics, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and Laplacian variance, were also evaluated. RESULTS: SR-UTE demonstrated superior image quality compared with conventional UTE, with higher SNR and CNR in patients with severe emphysema (both p < 0.05). For nodules < 6 mm, SR-UTE achieved a higher detection rate than UTE (81.8% vs. 54.5%, p < 0.05), with greater improvement for ground-glass nodules in severe emphysema (66.7% vs. 33.3%). Both UTE and SR-UTE achieved 100% sensitivity for nodules > 8 mm. SR-UTE showed better agreement with CT for nodule size measurement, with higher intraclass correlation coefficients across emphysema subgroups (0.89-0.93 vs. 0.84-0.88 for UTE) and reduced measurement bias. In longitudinal analysis, SR-UTE more accurately reflected CT-derived nodule size changes and demonstrated higher reproducibility than UTE (ICC 0.90 vs. 0.82). CONCLUSION: SR-UTE improved the detection of small and subsolid pulmonary nodules and provided more reliable longitudinal size assessment than UTE in patients with emphysema. These findings support the potential role of SR-UTE MRI in MRI-based surveillance of pulmonary nodules.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=18; title_english_function_words=3; title_english_share=0.1667; title_reads=english; abstract_words=285; abstract_english_function_words=71; abstract_english_share=0.2491; abstract_reads=english; language_check=metadata_listed