Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Computer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography

Kyung Nyeo Jeon; Jin Mo Goo; Chang Hyun Lee; Youkyung Lee; Ji Yung Choo; Nyoung Keun Lee; Mi-Suk Shim; In Sun Lee; Kwang Gi Kim; David S. Gierada; Kyongtae T. Bae (2012). Investigative Radiology

DOI 10.1097/rli.0b013e318250a5aa

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: The aim of this study was to evaluate whether a computer-aided diagnosis (CAD) system improves interobserver agreement in the interpretation of lung nodules at low-dose computed tomography (CT) screening for lung cancer. MATERIALS AND METHODS: Baseline low-dose screening CT examinations from 134 participants enrolled in the National Lung Screening Trial were reviewed by 7 chest radiologists. All participants consented to the use of their deidentified images for research purposes. Screening results were classified as positive when noncalcified nodules larger than 4 mm in diameter were present. Follow-up evaluation was recommended according to the nodule diameter: 4 mm or smaller, more than 4 to 8 mm, and larger than 8 mm. When multiple nodules were present, recommendations were based on the largest nodule. Readers initially assessed the nodule presence visually and measured the average nodule diameter manually. Revision of their decisions after reviewing the CAD marks and size measurement was allowed. Interobserver agreement evaluated using multirater κ statistics was compared between initial assessment and that with CAD. RESULTS: Multirater κ values for the positivity of the screening results and follow-up recommendations were improved from moderate (κ = 0.53-0.54) at initial assessment to good (κ = 0.66-0.67) after reviewing CAD results. The average percentage of agreement between reader pairs on the positivity of screening results and follow-up recommendations per case was also increased from 77% and 72% at initial assessment to 84% and 80% with CAD, respectively. CONCLUSION: Computer-aided diagnosis may improve the reader agreement on the positivity of screening results and follow-up recommendations in the assessment of low-dose screening CT.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=23; title_english_function_words=7; title_english_share=0.3043; title_reads=english; abstract_words=254; abstract_english_function_words=92; abstract_english_share=0.3622; abstract_reads=english; language_check=metadata_listed